IR Energy EvenTube ETS Installation, Operation And Service Instructions Download Page 3

S

ERIES 

E

VEN

-T

UBE

 

10-03-2017 

 

DANGER - CARBON MONOXIDE HAZARD

 

This appliance can produce carbon monoxide which has no odor. 

Using it in an enclosed space can kill you.  

Never use this appliance in an enclosed space such as a camper, tent, car or home. 

 

 

WARNING - ELECTRICAL GROUNDING INSTRUCTIONS

 

This heater is equipped with a three-prong (grounding) plug for your protection against shock 
hazard and should be plugged directly into a properly grounded three-prong receptacle. Do not 
cut or remove the grounding prong from this plug. 

Keep any electrical supply cord away from any heated surfaces. 

 

 

 

 

 

 
 

 

CAUTION - MAINTENANCE INSTRUCTION

 

1.  Keeping the appliance area clear and free from combustible materials, gasoline and other 

flammable vapors and liquids. 

2.  Not obstructing the flow of combustion and ventilation air. 
3.  Visually checking burner flames. 
4.  Cleaning the appliance, including special surfaces, with recommended cleaning agents, if 

necessary. 

Check the maintenance section in this manual for additional instructions. 

CAUTION - INSTALLATION

 

This appliance shall be used only in a well-ventilated space and shall not be used in a building, 
garage or any other enclosed area.  

The appliance may be installed with shelter no more inclusive than: 

1.  With walls on all sides, but with no overhead cover. 
2.  Within a partial enclosure which includes an overhead cover and no more than two 

side walls. These side walls may be parallel, as in a breezeway, or at right angles to 
each other. 

3.  Within a partial enclosure which includes an overhead cover and three side walls, as 

long as 30 percent or more of the horizontal periphery of the enclosure is permanently 
open. 

Summary of Contents for EvenTube ETS

Page 1: ...switches 3 Extinguish any open flame 4 Immediately call your gas supplier OWNER INSTALLER Retain this Manual ensure available for Service Improper installation adjustment alteration service or mainte...

Page 2: ...IONAL DETAILS ETS 60 80 100 11 INSTALLATION REQUIREMENTS POWER GAS SPECIFICATIONS 12 CLEARANCE TO COMBUSTIBLES 13 HEATER MOUNTING 14 VENTING 14 INSTALLATION CODE REQUIREMENTS 15 INSTALLATION INSTRUCTI...

Page 3: ...vapors and liquids 2 Not obstructing the flow of combustion and ventilation air 3 Visually checking burner flames 4 Cleaning the appliance including special surfaces with recommended cleaning agents...

Page 4: ...ised when in the area of this heating appliance Playing or running around the structure should be strictly forbidden Clothing or other flammable materials should not be hung on or near this heater Any...

Page 5: ...s heater is approved for outdoor installation only Not for use in residential dwellings refer to Rating plate Gas Supply Lines Gas supply pipe sizing must be in accordance with the National Fuel Gas C...

Page 6: ...ter Components for ETS 50 8 32 x 3 8 Screws QTY 55 Grill QTY 1 Burner Head with Service Cover 5 16 Nut 5 16 Lock Washer Gasket QTY 4 QTY 4 QTY 1 Burner Hanger QTY 1 Vent Hanger QTY 1 Vent Terminal QTY...

Page 7: ...7 10 03 2017 Specifications Heater Components for ETS 50 86 Flanged Tube QTY 1 Secondary Reflector QTY 1 Burner Head Reflector QTY 1 30 Deco Grille QTY 1 60 Deco Grille QTY 1 Deco Grille Support QTY 1...

Page 8: ...S 60 80 100 Burner Head with Service Cover 5 16 Nut 5 16 Lock Washer Gasket QTY 4 QTY 4 QTY 1 8 32 x 3 8 Screws QTY 55 Grill QTY 1 Burner Hanger QTY 1 Middle Hanger QTY 1 Vent Hanger QTY 1 Vent Termin...

Page 9: ...fications Heater Components ETS 60 80 100 continued Burner Head Reflector QTY 1 4 Extension Tube QTY 1 10 Flanged Tube QTY 1 Primary Reflector QTY 1 Secondary Reflector QTY 1 Deco Grille QTY 3 Deco Gr...

Page 10: ...SERIES EVEN TUBE 10 10 03 2017 Specifications Dimensional Details ETS 50 Note All dimensions are in inches...

Page 11: ...SERIES EVEN TUBE 11 10 03 2017 Specifications Dimensional Details ETS 60 80 100 Note All dimensions are in inches...

Page 12: ...tem at test pressures in excess of psig 3 5 kPa The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas s...

Page 13: ...onsidered combustible even though flame proofed fire retardant treated or plastered Adequate clearance to sprinkler heads must be maintained NOTE Sprinkler head heat fuse link performance may alter wi...

Page 14: ...ket It is critical that the heater is prevented from swaying and putting stress on the gas connection Also be sure to check local codes for seismic bracing requirements for outdoor heating equipment N...

Page 15: ...ectrical Code ANSI NFPA 70 in the USA CSA C22 1 Canadian Electrical Code in Canada Check for gas leaks at all connections with appropriate soap solution Do not use high pressure above psig to test the...

Page 16: ...of the job site will usually indicate a logical installation order However time and expense can be saved if installation is begun at the most critical dimension watching for interference from overhead...

Page 17: ...SERIES EVEN TUBE 17 10 03 2017 Installation Instructions Step 2 Step 3 10 Flanged Tube Face the Tube s weld seam downwards at a 6 o clock position Burner Hanger...

Page 18: ...SERIES EVEN TUBE 18 10 03 2017 Installation Instructions Step 4 Step 5 Burner Hanger Middle Hanger Assembly Burner Hanger Middle Hanger...

Page 19: ...ns Step 6 Step 7 Coupling Torque to 15 25 ft lbs When installing orient band clamp lock bolts to the side at a 3 o clock or 9 o clock position to avoid contact with reflector Extension Tube 4 or Face...

Page 20: ...SERIES EVEN TUBE 20 10 03 2017 Installation Instructions Step 8 Step 9 Vent Hanger Primary Reflector...

Page 21: ...SERIES EVEN TUBE 21 10 03 2017 Installation Instructions Step 10 Step 11 Slide Reflector and Burner Hanger against flange 8 32 x 3 8 screws...

Page 22: ...structions Step 12 Step 13 Vent Terminal Bend Baffle tab completely over end of Tube at 6 o clock position along the weld seam Baffle Slide Vent Terminal over Baffle tab Secure Vent to Tube using two...

Page 23: ...SERIES EVEN TUBE 23 10 03 2017 Installation Instructions Step 14 Step 15 8 32 x 3 8 screws Secondary Reflector...

Page 24: ...24 10 03 2017 Installation Instructions Step 16 Step 17 Remove Service Cover From Burner Head Note Ensure Burner Head is properly supported Use 5 16 washers and nuts to attach burner to flanged tube B...

Page 25: ...SERIES EVEN TUBE 25 10 03 2017 Installation Instructions Step 18 Step 19 Slide Burner Head Reflector over Burner Head 8 32 x 3 8 screws...

Page 26: ...SERIES EVEN TUBE 26 10 03 2017 Installation Instructions Step 20 Step 21 Attach Grill to Reflector and Burner Head 8 32 x 3 8 screws...

Page 27: ...SERIES EVEN TUBE 27 10 03 2017 Installation Instructions Step 22 Step 23 Re attach Service Door Fasten with acorn nut tuck this edge up and in Re attach Service Cover...

Page 28: ...E 28 10 03 2017 Installation Instructions Step 24 Step 25 Deco Grille Before installing the Deco Grilles bend all the tabs along one long side and both short sides of the Grille for easier fitment Glo...

Page 29: ...IES EVEN TUBE 29 10 03 2017 Installation Instructions Step 26 Step 27 Install Deco Grille Support first Face the tabs of this Support towards the Exhaust 8 32 x 3 8 screws 3rd Deco Grille 2nd Deco Gri...

Page 30: ...SERIES EVEN TUBE 30 10 03 2017 Installation Instructions Step 28 You should now have a fully assembled ETS 60 80 100...

Page 31: ...Installation Sequence ETS 50 Step 1 ETS 50 Step 2 ETS 50 30 Deco Grille Carefully remove the heater from box Before installing the Deco Grilles bend all the tabs along one long side and both short si...

Page 32: ...TUBE 32 10 03 2017 Installation Instructions Step 3 ETS 50 Step 4 ETS 50 End Cap 8 32 x 3 8 screws Face tabs of this Support towards the exhaust Install Deco Grille Support first 60 Deco Grille 8 32 x...

Page 33: ...SERIES EVEN TUBE 33 10 03 2017 Installation Instructions You should now have a fully assembled ETS 50...

Page 34: ...laced it must be replaced with wiring having a rating of at least 105 C temperature service and 600 volts capability NOTE If any of the original wire as supplied with the appliance must be replaced it...

Page 35: ...responding wires on Patio Heater Yellow Hi Brown Low Blue Manual Line Switch with Hi LO wiring diagram Two Stage Switch wiring diagram Notes Using 2 Stage witch P N EE020 Max 5 heaters per 1 switch Al...

Page 36: ...d the gas valve remains open The sparking stops when the flame signal is established 7 If no flame is detected the gas valve closes and a 30 sec inter purge period begins After the inter purge the mod...

Page 37: ...ged for service other than routine maintenance Be sure exhaust vent terminal and fresh air inlet grill are free from obstructions If either is restricted the safety air switch will not operate properl...

Page 38: ...ice person are required Check to see if gas lines were properly purged of air Check inlet and outlet gas pressure during ignition period Check for proper orifice and air plate Burner Does Not Stay Lit...

Page 39: ...r Impeller Spin Freely IF PROBLEM PERSISTS CONTACT YOUR LOCAL IR ENERGY REPRESENTATIVE Verify Sense Electrode Verify Ground Verify Wiring Does 24V Occur At Valve During Ignition Trial Check Wiring and...

Page 40: ...58 Transformer 115V to 24VAC 40VA 5 CE291 CE028 CE028 CE021 For ETS 50 Air Switch w Bracket 0 50 w c For ETS 60 Air Switch w Bracket 0 78 w c For ETS 80 Air Switch w Bracket 0 78 w c For ETS 100 Air S...

Page 41: ...s warranty does not cover any shipping installation or other costs incurred in the repair or replacement of the product No materials will be accepted for return without authorization This warranty wil...

Reviews: