S
ERIES
E
VEN
-T
UBE
14
10-03-2017
Installation Requirements
This heater can be installed
between wood beams with minimum
distances as shown.
Air flow
MUST NOT
be restricted.
The space above the heater must
not be enclosed in order to allow air
for ventilation.
NOTE
: Surfaces between joists or flush with the heater must not exceed 32°C (90°F) above
ambient temperature.
Heater Mounting
The heater can be mounted in a variety of ways, using a combination of chain, IR mounting
bracket. It is critical that the heater is prevented from swaying and putting stress on the gas
connection.
Also, be sure to check local codes for
seismic bracing requirements for outdoor
heating equipment.
Note:
Minimum mounting height is 7’ in
Canada and 8’ in the US.
Venting
This heater does not require venting as it is approved for
OUTDOOR INSTALLATION ONLY
.
WARNING!
This heater is NOT approved for any indoor Residential application.
If in doubt of your application, consult with your local fire marshal or
gas authority having jurisdiction.
Indoor spaces include but are not limited to: attached garages,
solariums, living quarters etc.
1/2"
Trusses CANNOT be enclosed
Wood Beam
1/2"