GW-ETH-02A
Run errors
If the gateway is at least partially operable or if an error occurs during its operation it continues the execution and
indicates the run error.
During run error red LED is continuously on. Green LED flashes with the specific duty:
•
Run error 1 10 ms on, 1 s off
•
Run error 2 100 ms on, 100ms of
•
Run error 3 500 ms on, 500 ms off
Run error 1
•
Ethernet start error
Ethernet interface fatal error
•
Ethernet service error
Some of Ethernet services failed
•
Connection error
Connection with IQRF Cloud server failed (in the Datalogger mode only)
•
Registration error
Registration to IQRF Cloud server failed (in the Datalogger mode only)
•
Upload error
Error when uploading data to IQRF Cloud server (in the Datalogger mode only)
•
Download error
Error when downloading data from IQRF Cloud server (in the Datalogger mode only)
When the gateway indicates Run error 1, it is not able to communicate with the Cloud server due to one of previous
reasons, but it is still possible to receive and save data from IQRF side. To detect the Run error 1 type, the gateway
must be connected to IQRF IDE with the Status tab opened where the error type can be read.
Run error 2
•
IQRF SPI error
IQRF TR module is not responding.
When the gateway signalize Run error 2, it is not able to communicate with the IQRF side, nevertheless the
communication with IQRF Cloud server not affected
Run error 3
•
SD card error
© 2016 MICRORISC s.r.o.
www.iqrf.org
User_Guide_GW-ETH-02A_ 160208