QUICK START
Quick start with HWP without programming
This chapter is intended as a step-by-step guide to get familiar with DPA and HWP. The process is the same for all
hardware profiles, either Demo HWP with common transceivers (TR) or General HWP with Data controlled transceivers
(DCTR).
Demo HWP vs. General HWP versions
Limitations
•
Demo HWP is limited to max. 5 Nodes (with addresses 1 to 5). A node device having an unsupported address flashes
periodically red LED after reset.
•
Some Custom DPA handler events are not supported. See IQRF DPA Technical guide for specification.
•
Only one user peripheral
PNum = 0x20
with one command
PCmd = 0x00
is supported.
Extensions
•
Demo HWP supports the PWM peripheral (simple pulse-width modulated digital output).
•
Discovery and FRC processes are indicated by LEDs flashing by default.
DS-DPA-02 development set
To learn DPA usage, development set DS-DPA-02 can be used.
•
DCTR-72DAT
IQRF smart transceiver
6 pcs
•
CK-USB-04A
IQRF programmer and debugger
2 pcs
•
DK-EVAL-04A
Universal portable development kit for (DC)TR modules
4 pcs
•
CAB-USBABMICRO
Micro USB cable 18.5 cm
2 pcs
•
USB flash drive
Software and documentation
1 pc
1. Preparation
All SW, plug-ins, documentation etc. are available on the flash disk and on
www.iqrf.org/downloads
.
•
Prepare 5 pieces of DCTR-72DAT with OS 3.07D or higher as Nodes and one DCTR-72DAT module with OS
3.07D or higher as the Coordinator.
•
Prepare 4 (5) pieces of DK-EVAL-04A and 1 (2) piece(s) of CK-USB-04A.
•
Install IQRF IDE 4.30 or higher. Refer to chapter
Installation
above.
•
Launch IQRF IDE and open Project
HWP-demo.iqrfprj
from IQRF Startup package. All necessary files and
macros are included in the Project.
© 2015 MICRORISC s.r.o.
www.iqrf.org
Quick_Start_Guide_IQRF_ 150805