23
Chapter 6
– Replacing Filters
6.
With the palm of the hand, press down on
the filter and loosen the frame.
5.
Turn the frame over so it is upside down.
4.
Remove the filter clamps that secure the
filter in the frame by pulling these out of
the sliding grooves.
9.
Turn the frame over (right side up again)
and insert the new filter. Ensure that the
arrows on the filter label point upward.
11.
To reinsert frame 1, tilt it upwards at
an angle while progressively pushing
the frame back into the housing.
For details on how to close the hou sing,
please refer to section 6.3.
8.
Dispose of the used filter by placing it
into the plastic bag in which the new
filter is supplied (see section 6.7).
7.
Lift the frame from the filter.
10.
Make sure that the filter is inserted all the
way into the frame. Insert the clamps into
the sliding grooves inside the frame and
push them down, securing the filter into
place.
V5-Cell
Filter
Frame 2
1.
Open the locking arms, making sure they
are fully extended outward. For details,
refer to section 6.3.
2.
Opening the arms will release the top
housing modules. Remove the diffuser
and Frame 3. Then put these aside.
3.
Frame 2 contains the V5-Cell fil ter.
5.
Insert the new filter. "TOP" indicates the
filter's upright position. Ensure that "TOP"
is visible when filter is installed.
4.
Remove the used V5-Cell by lifting it out of
the frame (disposal see section 6.7).
Frame 3
Frame 2
Diffuser
6.5 Replacing the V5-Cell
TM
Filter (F2) – HealthPro Plus Only
6.
Put the frame back into the housing,
followed by frame 3 and the diffuser. For
closing refer to section 6.3.
Diffuser
Frame 2
Frame 3
12.
After a filter has been replaced, the Filter
Life Monitor must be reset from the
control panel (see section 4.4.8).
7.
After a filter has been replaced, the
Filter Life Monitor must be reset from the
control panel (see section 4.4.8).
Important: Black dust from V5-Cell can
stain. Wear rubber or plastic gloves and
protect clothing and other surfaces while
handling.