11 

 

Step 6 

Remove and clean the Impaktor 
Pull the center tab. Once removed, the 
Impaktor can be thoroughly cleaned with a 

soft brush or a vacuum cleaner fitted with a 
brush attachment. If required, the Impaktor 
can be cleaned further by rinsing under 
running water at a wahbasin and then letting 

it dry. After it has dried, the cleaned Impaktor 
can be inserted back into the inlet grille. 

 

 

 

Replace the Impaktor 
Ensure that the slots on the Impaktor match 

tabs on the inner side of the grille (the left 
and right sides are made different to ensure 
that the Impaktor is inserted the right way 
round). Hook the Impaktor slots underneath 

the grille’s tabs – the Impaktor will arch 
outwards. Press downwards onto the center 
of the Impaktor. 

 

 

 

Replace the inlet grille 

Locking levers open 

Ensure that both the locking levers are in the 
open position. 

 

Slide in the grille 

Take care that the tabs on inlet grille slot into 
the slide on both sides of the inlet opening. 
Gently slide the inlet grille back into position. 

 

Close locking levers 
Move  both  the  locking  levers  into  their 
respective closed positions. 

 

 

 

Repeat Steps 3 … 6

 

 

Repeat  the  process  for  the  remaining  two  filters.  Remember  that  you  can  rotate  the  purifier 
counterclockwise to gain easy access. 
 

 

Replace the front cover

 

 

Push the front cover back into place. The spigot on the inside of the front cover slides into socket in 
the inner cover. 

 

 

Summary of Contents for Atem X

Page 1: ...User Instructions IQAir Atem X User Instructions EN v00 19c...

Page 2: ...placing filters the appliance must be disconnected from the supply mains Do not use the product if the plug the supply cord or the appliance itself is damaged If the supply cord is damaged you must ha...

Page 3: ...ure heat sources This product contains high precision technology Do not drop tamper with nor expose to impact Floor standing installation of the product shall be on a stable level and horizontal surfa...

Page 4: ...44 Using Your Air Purifier 55 Install the App 55 The control panel 66 Air cleaning performance Manual mode 77 Air cleaning performance Smart Mode 77 Filter replacement 88 Technical Specifications 121...

Page 5: ...pp while the Air Quality Index is indicated on the purifier s control panel The built in PM2 5 sensor drives the purifier s Smart Mode Automatic control for optimal air cleaning performance The Atem X...

Page 6: ...very good air circulation to clean the whole room Installation Floor standing Place the purifier on the floor The stand s non slip feet ensure a steady stance on most floor surfaces Optionally mount t...

Page 7: ...ion within IQAir s AirVisual community Install the App Download and install the IQAir App on your Smartphone to control your IQAir Atem X You will need access to a Wi Fi network to connect to and cont...

Page 8: ...deactivate Smart Mode Light Touch to turn the control panel lighting ON OFF2 User inputs are acknowledged by a brief fade in out of all indicators This brief fade in out occurs also when the control p...

Page 9: ...ft most end of the control close to the minus symbol to select the lowest air cleaning performance level Touch anywhere on the control sets the respective performance level e g level 4 as shown Touch...

Page 10: ...eplaced soon make sure that you have a replacement filter set A red warning symbol tells you that the filter is full and needs to be replaced Unplug the power cord and stow it in cord channel before c...

Page 11: ...grille Consider that the Impaktor which is latched on the inside of the inlet grill could have trapped a lot of dust hair and lint Use a vacuum cleaner fitted with dust brush attachment to remove any...

Page 12: ...household waste Step 5 Insert the replacement filter Make sure that the filter s orientation tab is facing towards the front of the purifier Slide to the left Insert the filter into the inlet opening...

Page 13: ...und Hook the Impaktor slots underneath the grille s tabs the Impaktor will arch outwards Press downwards onto the center of the Impaktor Replace the inlet grille Locking levers open Ensure that both t...

Page 14: ...120 Volt version 120 V 60 Hz Power rating 110 W Sensors Particulate matter PM2 5 Temperature Humidity Dimensions Diameter 640 mm without stand Depth 220 mm Weight3 11 kg Dimensions Height 688 mm inclu...

Page 15: ...perienced radio TV technician for help This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 th...

Page 16: ...for similar purpose Product Storage When not in use store your Atem X in a clean dry place Use the original packaging for optimal storage Cleaning Unplug the power cord before cleaning Use a dry lint...

Reviews: