background image

It is recommended that the lamp is fitted before the lantern is fixed to the wall. 
Fit the lamp as follows. 
Release the hexagonal nuts on the top cover of the lantern see Diagram A and remove the top 
cover. 

IMPORTANT! 

If you intend to benefit from the addition  of the OPTIONS module, please refer to the OPTIONS 
control module instruction manual for advice on assembly and set up.
If you intend not to use the OPTIONS module,the blanking plate 

MUST

 be fitted to maintain 

Safety Regulations! 
Fit Blanking Plate supplied by simply inserting into the aperture shown on diagram B. Ensure 
blanking plate is fully secured to ensure a watertight seal. There will be an audible click and the 
cover will fit securely into its circular aperture. 
If the blanking plate is missing from this product, DO NOT INSTALL, please contact the 
Consumer Helpline below.

SECTION TWO

SELECTING THE LOCATION

If it is your intention to use the OPTIONS control module, for best results mount at height of 
1.8m. See OPTIONS module instruction manual for more details.

SECTION THREE

 INSTALLATION 

After choosing a suitable location (see previous section) install the unit as follows:

The unit is suitable for connection to a 240V 50Hz electricity supply. It is suggested that 
3-core round flexible cable of 1mm² gauge is used. An internal switch should be installed to 
switch the power to the unit ON & OFF. This allows the lantern to be easily switched off when not 
required or for maintenance purposes.

*** IMPORTANT ***

Switch off the electricity at the fuse box by removing the relevant fuse or switching off 

the circuit breaker before proceeding with the installation.

PARTS INCLUDED 

- Luminaire
- Instruction manual. Please keep safe for future reference.
- Wall fixing screws and wall plugs
- Blanking Plate
- Wall plate

TOOLS & PARTS NEEDED 

- Electric/hand-held drill & bits.
- Terminal or Electricians screwdriver
- Large slotted/philips screwdriver
- Wire cutters
- 1.0mm sq. round flexible cable
- 60W Max GLS ES Lamp (refer to Section 5 for further details)
This lantern is for outdoor use only.  Unit must be mounted on a non-flammable surface as a 
fixed luminaire, and is not suitable for portable use.The unit can get very hot during use.  Ensure 
the unit has cooled before handling.Ensure adequate ventilation space is allowed between the 
unit and any object above, in front or to either side of the unit. Suggested space is 0.5m above, 
0.3m to either side & 1.0m in front. Do not attempt to install during wet weather, if you are 
suffering from nausea or dizzy spells or on medication with similar side effects
If in any doubt, consult a qualified tradesperson or electrician.

Summary of Contents for E-489B

Page 1: ...9B IQ Europe Limited Sandbeck Lane Wetherby LS22 7TW Visit us at www iq europe co uk Installation helpline 0871 717 1100 I N S T A L L E R G U I D E Bosun Options 60W Steel Lantern V2 0 1 07 IQ SNL SL01 100 ...

Page 2: ...lly exposed or harsh environmental conditions If the buyer is resident in the EU the product or its replacement will be returned to the buyer at the expense of IQ This guarantee excludes liability for discolouration of paint or plastic or any user replaceable parts and in particular lamps glass panels or globes lanterns It does not confer any rights other than those expressly set out above and doe...

Page 3: ...oose from the following Night Sensor the unit will illuminate at a level of darkness set by you and will remain illuminated throughout the night switching itself off at dawn This mode is ideal for use with low energy lamps but check your OPTIONS Light Fitting to see if Low Energy lamps are capable of being installed Motion Sensor Mode the unit will begin to operate at a level of darkness set by yo...

Page 4: ...tricity supply It is suggested that 3 core round flexible cable of 1mm gauge is used An internal switch should be installed to switch the power to the unit ON OFF This allows the lantern to be easily switched off when not required or for maintenance purposes IMPORTANT Switch off the electricity at the fuse box by removing the relevant fuse or switching off the circuit breaker before proceeding wit...

Page 5: ... the top cover and secure the two fixing screws Ensure the decorative handle is located in the slot at the rear of the lantern Fully secure the lantern fixing screws See Diagram A Installation is complete The unit is ready for mounting to the wall The wall bracket is packed seperately remove from packaging Based on the location of your incoming cable use the wall plate as a template and mark the p...

Page 6: ...t in resolving your query SECTION SIX TROUBLESHOOTING GUIDE PROBLEM Lantern did not operate at all SOLUTION Check that the power is switched ON at the circuit breaker internal wall switch Turn OFF the power to the unit and check the wiring connections as per the diagram see previous section 3 Ensure no connections are loose Check the lamp If the lamp has failed replace Ensure that the lamp is seat...

Page 7: ...N E L A D C B hexagonal cover fixing nuts and washers x 2 blanking plate lantern fixing screw x 2 fast fix connector wall fixing hole wall fixing hole cable inlet LEN ...

Page 8: ...wattage lamp This could save you up to 40 in running costs whilst also conserving pre cious natural resources LIGHT POLLUTION CONSIDERATE LIGHTING Please be aware of the annoyance over lighting an area can cause to your immediate neighbours Light pollution caused by incorrectly installing a lantern or over lighting an area can be limited by carefully considering the location and position of your l...

Reviews: