CONNECTION

It is recommended that the circuit is protected by a 5A max fuse or circuit breaker.
It is recommended that this product is connected to fixed wiring only. 
Connect the cable to the terminal block on the unit as follows (see connection diagram): 

 

LIVE (Brown)   

 

L

     

EARTH (Green/Yellow)  

 

 

NEUTRAL (Blue)   

 

N

Ensure that the connections are secure and the terminal block is securely located on its mounting 
posts.

This product uses a fast fix connector and it is imperative the connector is aligned when 
assembling the lantern onto the wall plate.
Lift the lantern onto the wall plate, ensure that the screws at either side of the lantern bracket 
are aligned with the holes in the wall plate, this will ensure the pin connections of the fast fix 
connector are aligned with their receptacles. 
Replace the top cover and secure the two fixing screws. 
Ensure the decorative "handle" is located in the slot at the rear of the lantern.
Fully secure the lantern fixing screws See Diagram A.
Installation is complete.

The unit is ready for mounting to the wall. 
The wall bracket is packed seperately, remove from packaging.

Based on the location of your incoming cable,use the wall plate as a template and mark the 
position of the mounting holes. See diagram C.

Ensure the wall plate is in the correct orientation by referring to the to arrow marked "TOP" See 
Diagram C, note that the wall plate is placed in a VERTICAL position for this product.
 
Drill holes and insert wall plugs into the holes. 

Pierce and pass the cable through the grommet before securing the wall plate to the wall. 

Fit the wall plate to the wall
Do not overtighten, if using a power screwdriver ensure it is set to the lowest torque setting to 
prevent damage to the wall plate.

CONNECTION DIAGRAM

Mains 
Supply

Isolation 
Switch

N

E

L

N

E

L

Summary of Contents for E-489B

Page 1: ...9B IQ Europe Limited Sandbeck Lane Wetherby LS22 7TW Visit us at www iq europe co uk Installation helpline 0871 717 1100 I N S T A L L E R G U I D E Bosun Options 60W Steel Lantern V2 0 1 07 IQ SNL SL01 100 ...

Page 2: ...lly exposed or harsh environmental conditions If the buyer is resident in the EU the product or its replacement will be returned to the buyer at the expense of IQ This guarantee excludes liability for discolouration of paint or plastic or any user replaceable parts and in particular lamps glass panels or globes lanterns It does not confer any rights other than those expressly set out above and doe...

Page 3: ...oose from the following Night Sensor the unit will illuminate at a level of darkness set by you and will remain illuminated throughout the night switching itself off at dawn This mode is ideal for use with low energy lamps but check your OPTIONS Light Fitting to see if Low Energy lamps are capable of being installed Motion Sensor Mode the unit will begin to operate at a level of darkness set by yo...

Page 4: ...tricity supply It is suggested that 3 core round flexible cable of 1mm gauge is used An internal switch should be installed to switch the power to the unit ON OFF This allows the lantern to be easily switched off when not required or for maintenance purposes IMPORTANT Switch off the electricity at the fuse box by removing the relevant fuse or switching off the circuit breaker before proceeding wit...

Page 5: ... the top cover and secure the two fixing screws Ensure the decorative handle is located in the slot at the rear of the lantern Fully secure the lantern fixing screws See Diagram A Installation is complete The unit is ready for mounting to the wall The wall bracket is packed seperately remove from packaging Based on the location of your incoming cable use the wall plate as a template and mark the p...

Page 6: ...t in resolving your query SECTION SIX TROUBLESHOOTING GUIDE PROBLEM Lantern did not operate at all SOLUTION Check that the power is switched ON at the circuit breaker internal wall switch Turn OFF the power to the unit and check the wiring connections as per the diagram see previous section 3 Ensure no connections are loose Check the lamp If the lamp has failed replace Ensure that the lamp is seat...

Page 7: ...N E L A D C B hexagonal cover fixing nuts and washers x 2 blanking plate lantern fixing screw x 2 fast fix connector wall fixing hole wall fixing hole cable inlet LEN ...

Page 8: ...wattage lamp This could save you up to 40 in running costs whilst also conserving pre cious natural resources LIGHT POLLUTION CONSIDERATE LIGHTING Please be aware of the annoyance over lighting an area can cause to your immediate neighbours Light pollution caused by incorrectly installing a lantern or over lighting an area can be limited by carefully considering the location and position of your l...

Reviews: