IPTC Albatross™ DEX28-GE2P – Quick Installation Guide

 

1

DEX28-GE2P – Quick Installation Guide 

 

A) Switch Side 

1.

 

Connect DEX28 to IP network 

2.

 

Connect DEX28 console port to PC/terminal using provided DB9-RJ45 adapter 

3.

 

Connect the power to DEX28 

4.

 

Configure static or DHCP IP address setting using PC/terminal 

5.

 

Connect telephony ports to MD110 ELU28 board 

6.

 

Connect to DEX28 using web browser, and optionally configure users and port parameters 

B) Extension Side 

1.

 

Connect DEX28 to IP network 

2.

 

Connect DEX28 console port to PC/terminal using provided DB9-RJ45 adapter 

3.

 

Connect the power to DEX28 

4.

 

Configure static or DHCP IP address setting using PC/terminal 

5.

 

Connect telephony ports to Ericsson Digital Telephone Sets (DTS) 

6.

 

Proceed with configuration using web browser, and configure DTS connection parameters. 
At least Switch Side DEX28 Gateway IP address should be configured. 

 
Note: It is recommended to assign static IP address to Switch Side DEX28 gateway. IP address of the Extension 
Side DEX28 can be dynamic and is not important unless intermediate firewalls should be accounted. 

 

IP

Switch Side 

Extension Side 

GE2P

 

/ GW 

GE2P

 

/ EXT 

Ethernet Switch or Hub

IP 

Power Supply 

Ada

pter 

RJ45-DB9 Adapter 

Power Supply 
Cord 

RJ45 STP 
Patch Cable 

Summary of Contents for Albatross DEX28-GE2P

Page 1: ... to PC terminal using provided DB9 RJ45 adapter 3 Connect the power to DEX28 4 Configure static or DHCP IP address setting using PC terminal 5 Connect telephony ports to Ericsson Digital Telephone Sets DTS 6 Proceed with configuration using web browser and configure DTS connection parameters At least Switch Side DEX28 Gateway IP address should be configured Note It is recommended to assign static ...

Page 2: ...g RJ45 DB9 adapter One RJ45 to DB9 RS232 adapter black The following cables will be locally sourced Cables between DTS and DEX28 GE2P configured in Extension Side mode Cables between PBX and DEX28 GE2P configured in Switch Side mode Unpacking Check that the equipment has not been damaged during transport Damaged equipment that needs to be replaced or repaired at a service shop must be reported imm...

Page 3: ...le to Ethernet hub switch directly Connection can be also made indirectly through patch panel or wall outlet Connect the Power and Turn On the Gateway Caution Be sure to use the power supply that was supplied with your DEX28 gateway To connect the AC adapter to the DEX28 gateway and turn it on follow the steps 1 Connect one end of the power supply cable to the gateway s input jack 2 Connect the ot...

Page 4: ...l Start Programs Accessories Communications HyperTerminal RS232 settings should be 115200 8 n 1 with flow control disabled HyperTerminal should start and after pressing enter following welcome screen from DEX28 GE2P should appear Type in username setup and press enter then type in password admin and press enter ...

Page 5: ... DEX28 to PBX Direct connection to PBX when DEX28 is placed in patch panel room Indirect connection to PBX Note Instead of RJ45 RJ11 or RJ45 RJ45 RJ11 RJ11 Flat Patch Cable can be used RJ11 Wall Outlet RJ45 RJ11 Flat Patch Cable RJ45 RJ45 Patch Cable Patch Panel Patch Panel ...

Page 6: ...mage can happen to either DEX28 unit PBX ELU board or both Direct connection of DTS to DEX28 GE2P in the same room Indirect connection of DTS to DEX28 GE2P when DEX28 is placed in patch panel room Note Instead of RJ45 RJ11 or RJ45 RJ45 RJ11 RJ11 Flat Patch Cable can be used RJ45 Wall Outlet Patch Panel RJ45 RJ45 Patch Cable RJ45 RJ11 Flat Patch Cable RJ45 RJ11 Patch Cable ...

Page 7: ...e screen should appear Select Configure device option and type in username and password then click OK If you have not set a System password before the device will accept the default password admin and username system Remember that all passwords and usernames are case sensitive If you have changed the System password but cannot remember it then you should configure device over serial RS232 cable co...

Page 8: ...C Albatross DEX28 GE2P Quick Installation Guide 8 Extension Connection Parameters The only mandatory Extension Side DEX28 parameter to be specified is Switch Side DEX28 IP address DEX28 Gateway IP address ...

Page 9: ... then following menu will be displayed on DTS to the user On character capable DTS On graphic capable DTS In case that DTS does not posses display to identify what button should be pressed some LED will be lit LED associated to Access 2 alt Line 2 and Inquiry will constantly lit LED associated to Access 1 alt Line 1 button will blink ...

Page 10: ... Console RS232 Port DTS PBX Ports RJ45 DB9 1 RTS 8 CTS 2 DTR 6 DSR 3 TXD 2 RXD 4 GND 5 GND 5 GND 5 GND 6 RXD 3 TXD 7 DSR 4 DTR 8 CTS 7 RTS or Power Supply 48VDC Input Reset Button To DTS or SSW Ethernet 10 100 Base T LAN Port RS232 Console 1 TX 2 TX 3 RX 4 n c 5 n c 6 RX 7 n c 8 n c 1 n c 2 n c 3 n c 4 Ring 5 Tip 6 n c 7 n c 8 n c ...

Page 11: ...ng surfaces Do not allow anything to rest on the power cord Do not locate this product where the cord will be abused by persons walking on it Unplug the product from the wall outlet before cleaning Use a damp cloth for cleaning Do not use cleaners or aerosol cleaners Do not operate the system if chemical gas leakage is suspected in the area Use telephones located in some other safe area to report ...

Page 12: ...transmission D4oIP D channel Protocol for Ericsson ELU 2B D IP packets are tagged for network traffic prioritization using IP Precedence or Diffserv IEEE 802 1q VLAN Management SSH HTTP SNMP Telnet FTP Optional IPSec for VPN System Software Host Linux Kernel v2 6 x DSP Real Time DSP BIOS Full IPv4 and IPv6 protocol stacks with QoS and VLAN Management and Utilities SSH RS 232 Console Interface HTTP...

Page 13: ...15 Class B EN 55022 1998 A1 2000 and A2 2003 Class B Information technology equipment Radio disturbance characteristics EN 55024 1998 A1 2002 and A2 2003 Information technology equipment Immunity characteristics Warranty and Support 12 months limited warranty for parts and labor including advance replacement when unit is shipped back for repair 18 months corrupted flash repair replacement Unlimite...

Page 14: ...ibility PBX MD110 all ELU25 ELU28 BP ELU D Supported Ericsson DTS DBC 600 DBC 199 Series DBC 601 DBC 631 DBC 661 DBC 662 DBC 663 DBC 199 DBC 200 Series DBC 201 DBC 210 DBC 211 DBC 202 212 DBC 203 213 DBC 214 DBC 220 Series DBC 220 DBC 222 DBC 223 DBC 224 DBC 225 ...

Reviews: