![ipf electronic PY740020 Manual Download Page 58](http://html1.mh-extra.com/html/ipf-electronic/py740020/py740020_manual_2088887058.webp)
MANUAL [
PY740020/21
]
• Subject to alteration! Version: 10.10.2018
ipf electronic gmbh
• Kalver Straße 25 - 27 • 58515 Lüdenscheid
│
Tel +49 2351 9365-0 • Fax +49 2351 9365-19
│
6.5.3 Sync-In / Trigger
The measurement and signal output can be interrupted with the Sync-In input by connecting with high. As long
as Sync-In is on high, the sensor delays the next measurement (hold) and reduces the power of the laser
beam.
•
The sensor checks Sync-In before every measurement
•
The previous measurement cycle is always completed first, even if Sync-In is on high
•
During the waiting time (hold), the power of the beam is reduced, and the output signal is 4mA or 0V
•
To return the sensor to measuring mode, Sync-In must be set from high to low
•
Sync-In must remain on low for at least 5 µs in order for the sensor to begin measuring again
•
If Sync-In switches from high to low level, the response time lasts takes longer in the first
measurement cycle
Sync-In
Level
Measurement
Sync-In low
0…2.5 V
Run
Sync-In high
8 V…UB (operating voltage)
Hold
Application example: Reciprocal influence
Only the laser beam of Sensor1 may be in the measuring field of Sensor1. The laser beam of Sensor2 must
be outside the measuring field of Sensor1.
If it is not possible to prevent several sensors from affecting each other through appropriate installation,
however, the sensors affecting each other can be operated asynchronously using the the Sync-In cable. The
superordinate control generates the signals for this.