4.7 Practical zero point search
In case of angled installation, the zero point (0mm) oft he K axis shifts out of the center of the red visible laser
line.
4.8 Installation accessories
To ensure optimal mounting, the mounting bracket AP000043 is available as an accessory. This bracket fits
best with the ball-head holder AY000143.
The sensor can be aligned within the entire pivoting radius of the ball-head.
4.8.1 Mounting kit for PY74 series
With the mounting bracket AP000043 and the ball-head AY000143 the sensor can be mounted quickly and
easily in any orientation.
NOTE
The "Edge L rise or Edge R rise" mode, for example, can be used as an aid to find
the zero point. Now an object is slowly pushed toward the presumed zero point.
The zero point is reached by the left rising edge of the object when the value 0 mm
is shown on the sensor display and the yellow LED switches.