5.11.4 RESET
This resets all settings in sensor parameters to the factory settings.
MEASUREMENT TYPE = Edge L rise
OBJECT HEIGHT
= > 4 mm
OBJECT
= Light
PRECISION
= Standard
FLEX MOUNT
= Not activated (standard installation A = 0°, D = End of measuring range Sde)
MEASURING FIELD = Max. values (trapezium)
DIGITAL OUT
= Threshold (0mm, Active high)
DISPLAY LIGHT
= OFF after 5 min.
LANGUAGE
= English
5.12 SETTING
The settings entered in the sensor can be applied, stored or displayed here.
5.12.1 APPLY
The settings saved under SAVE can be activated here.
•
Setting 1
•
Setting 2
•
Setting 3
5.12.2 SAVE
The settings entered in the sensor can be stored here.
Three storage spaces are available.
•
Setting 1
•
Setting 2
•
Setting 3
5.12.3 SHOW
SHOW displays the setting values.
SHOW ACTIVE
Displays the active settings.
SHOW SETTING 1-3
Displays the settings stored in storage spaces 1-3