MANUAL
• Subject to alteration! Version: June 2015
ipf electronic gmbh
• Rosmarter Allee 14 • 58762 Altena
│
Tel +49 2351 9365-0 • Fax +49 2351 9365-19
│
[email protected] • www.ipf-electronic.
com
2
1 General Notes
Rules for proper usage
This product is a precision device which has been designed for the detection of
objects and parts. It generates and provides measured values issued as electrical
signals for following systems.
Unless this product has not been specifically marked it may not be used in hazard-
ous areas.
Set-Up
Installation, mounting and adjustment of this product may only be executed by
skilled employees.
Installation
Only mounting devices and accessories specifically provided for this product may
be used for installation.
Unused outputs may not be connected.
Unused strands of hardwired sensors must be isolated. Do not exceed the maxi-
mum permissible bending radius of the cable.
Before connecting the product electrically the system must be powered down.
Where screened cables are mandatory, they have to be used in order to assure
EMI protection. When assembling connectors and screened cables at customer
site the screen of the cable must be linked to the connector housing via a large
contact area.
Laser Safety
•
The laser diode installed in the PT65 emits visible red laser lights. This laser belongs to the Class 2 laser standard
specified by the IEC 60825-1.
•
Max. average output power < 1 mW.
•
Laser radiation, do not stare into beam.
•
To avoid uncontrolled laser exposure we recommended stopping the beam with a matte object.
•
For laser safety reasons, the voltage supply of the sensors must be turned off when the whole system or the
machine is turned off.
•
Safety concept information and limiting parameters as published in the sales documentation apply at all times.