background image

the teach-in procedure relating to through-beam sensor operation: 

1. Aim the sensor towards the background and/or the machinery part.

2. Connect the Teach-In line (white, PIN 2) to + UB for longer than 2 seconds (however less than 5 seconds). The red LED flashes.

3. Connect the Teach-In line again to +UB for a short period.

4. If the sensor is intended to work as a make contact (output switched if an object is detected), then connect the Teach-In line 

again for a short period with +UB. Otherwise the device works as a break contact.

5. The Teach-In process is completed as soon as the red LED is lit for 2 seconds.

6. If the sensor is `teached in' outside of its detection range, a warning signal will be displayed (rapid flashing of the red 

LED). The device is then set at its maximum operate distance.

teach-in of the ON – / OFF position (2-point Teach-In) 

1. Aim the sensor towards the background and/or the machinery part.

2. Connect the Teach-In line (white, PIN 2) to + UB for longer than 5 seconds with +UB. The red LED flashes rapidly.

3. Connect the Teach-In line again to +UB for a short period.

4. Place the object between the sensor and the background and connect the Teach-In line to +UB again for a short period.

5. The device works as a make contact (output switched if an object is detected). If points 3 and 4 are swapped around, the 

device works as a break contact.

If the sensor is `teached in' outside its detection range, or the margin between the teach positions is too narrow for a 

secure operation, a warning signal will be displayed (rapid flashing of the red LED). The sensor will then retain its previous 

setting.

alignment mark 

Connect the teach-line to +UB for more than 10 seconds. The red LED flashes rapidly

.

 Break the connection.

 

If the red LED goes out now, this means that no signal is being picked up by the receiver. A LED that flashes slowly means that there 

is a weak signal. A LED that flashes fast means that there is a strong signal.  If the LED is illuminated permanently, then the alignment 

is ideal. In order to return to the normal mode, connect the Teach-In line for a short period with +UB. 

soiling indicator 

If the sensor has been `teached in' as a make contact, the red LED flashes if the sensor is soiled. 

notes:

  

 The above status information applies to a „plus switching“ (pnp) connection. 

For a „minus switching“ (npn) connection the status information has to be inverted. 

Under normal operations, the Teach-In line must be grounded (0V)!“ 

electric connection 

dimension drawing 

e.g. 

VK200375

suitable cable socket: 

Warning:  

Never use these devices in applications where the safety of a person depends on their 

functionality.

 

* transmitter axis

 

wire colors

: bn = brown (1), wh = white (2), bu = blue (4), bk 

= black (4)

 

Teach-in-input 

switching output 

MANUAL

 • Subject to alteration! Version:  

November 2012

ipf electronic gmbh

 • Rosmarter Allee 14 • 58762 Altena 

 Tel +49 2351 9365-0 • Fax +49 2351 www.ipf-electronic.com 