1  Introduction 

All technical information, descriptions and illustrations contained in this ‘Operating, Maintenance, and 
Installation Manual’ remain our property and shall not be used differently than for operating this system, 
nor shall they be copied, reproduced or passed on to third parties or brought to their notice without our 
prior written consent. 
 
The  information  represented  in  this  manual  is  in  keeping  with  current  standards  and  is  subject  to 
subsequent alterations. 
 
This manual contains important instructions referring to safe installation, commissioning, operation, and 
maintenance. 
Read this manual thoroughly, before starting up the gateway, and observe the instructions. 
 
In order to comply with the guidelines for electro-magnetic compatibility, only CE-certified components 
are used in compliance with project-specific requirements. 
 
Please note that the hardware platform (SEC3ER) is not protected against lightning and the operator 
should, if desired, take appropriate protective precautions. 
The  addition  of  our  RS-232  isolator  provides  efficient  protection  of  your  data  and  equipment  against 
external influences. We will be pleased to draw up a non-binding offer for you. 
 
Finally we want to draw your attention to the fact that any warranties will be invalid in the event that: 
 

 

Operation,  servicing,  and  maintenance  are  not  carried  out  accurately  according  to  the 
instructions; repairs are not carried out by our personnel or without our prior written consent. 

 

Commissioning is not carried out by our personnel or we have not given our approval for the 
commissioning or the commissioning is carried out by untrained personnel. 

 

The unit is used inadequately, incorrectly, negligently, or inappropriately or for a purpose other 
than originally intended. 

 

The serial number is removed from the product. 

 

For your protection, observe the following safety precautions when setting up your equipment: 

 

 

Follow all cautions and instructions marked on the equipment. 

 

Ensure that the voltage and frequency of your power source match the voltage and frequency 
inscribed on the equipment's electrical rating label. 

 

Never push objects of any kind through openings in the equipment. Dangerous voltages may 
be  present.  Conductive  foreign  objects  could  produce  a  short  circuit  that  could  cause  fire, 
electric shock, or damage to your equipment. 

 
 
 
 
 
 

All trade names or trademarks mentioned in this document are used for identification purposes only and 
are property of their respective owners. 

Summary of Contents for SEC3ER

Page 1: ...emberg Germany Edition June 2021 Version 1 0 Phone Fax Internet E mail 49 911 18 07 91 0 49 911 18 07 91 10 https www ipcomm de info ipcomm de SEC3ER 4 Port Ethernet Line Breaker General Operating Mai...

Page 2: ...4 Hardware Components 6 2 4 1 Mainboard 6 2 4 2 RS 232 RS 422 RS 485 Interfaces 6 2 4 3 Network Interfaces ETH0 ETH1 6 2 4 4 Ethernet Relays E1 E4 7 2 4 5 I O Interfaces 7 2 4 6 Flash Mass Storage 8...

Page 3: ...protection of your data and equipment against external influences We will be pleased to draw up a non binding offer for you Finally we want to draw your attention to the fact that any warranties will...

Page 4: ...on on all interfaces min 48 hours Communication disruptions transmission errors and every important component with regard to function temperature voltages etc are monitored Hundreds of restarts are ex...

Page 5: ...ontrol their communication state ON Manually switched on REMOTE Control via Software OFF Manually switched off In the switch position REMOTE software control is possible via a communication protocol o...

Page 6: ...s a RS 232 RS 422 RS 485 interface by the software SERIAL PORT RJ45 female connector Pin RS 232 RS 422 RS 485 1 DSR 2 RTS TXD Data 3 GND GND GND 4 TXD TXD Data 5 RXD RXD 6 DCD RXD 7 CTS 8 DTR Figure 4...

Page 7: ...y interface pair 2 4 5 I O Interfaces The embedded controller features eight digital inputs and eight digital outputs The digital inputs are equipped with overvoltage protection Digital input 9 pin mu...

Page 8: ...ts real time clock is buffered by a battery The durable lithium battery generally offers a lifespan of more than 5 years The default settings are designed in a way that the gateway can operate without...

Page 9: ...9 rack 3 Unscrew and lift the housing cover by loosening the corresponding nine screws It is recommended to use a Torx screwdriver of size T10 4 Pull the old battery out of the battery holder 5 When i...

Page 10: ...e is supplied with voltage The USR LED is freely configurable An imaginable function would be to display a particular connection status or more than one as an overall status 3 1 CPU LED The CPU LED vi...

Page 11: ...is lit communication is possible on the corresponding Ethernet interface relay closed If the green LED OFF is lit communication is not possible on the corresponding Ethernet interface relay open If th...

Page 12: ...gure 13 LEDs for digital inputs When the input level high is reached the input diagnostic LEDs DI 1 to DI 8 light up green 3 3 2 Digital Outputs Figure 14 LEDs for digital outputs If a digital output...

Page 13: ...Data Sheet A technical data sheet for the individual hardware models is available separately to this document In addition to pure technical data the document also contains information on approval and...

Page 14: ...remberg All rights reserved Germany 5 EU Declaration of Conformity An EU Declaration of Conformity for the individual hardware models is available separately for this document A current version of the...

Page 15: ...ration Power supply Value Description A 85 264 V AC E 9 60 V DC F 9 60 V DC EMV IEC 61850 3 RAM Flash Value Description A 256 MB 512 MB Flash Model Value Description A SEC3 The base model B SEC3PB The...

Page 16: ...on 1 0 IPCOMM GmbH 16 SEC3ER Manual Walter Bouhon Strasse 4 Copyright IPCOMM GmbH 2021 90427 Nuremberg All rights reserved Germany 7 SEC3ER Dimensions Figure 15 Dimensions front view SEC3ER Figure 16...

Reviews: