3.2  Status LEDs E1 

– E4 

 

Figure 12: LEDs E1 

– E4 

 
The status LEDs of the interfaces E1 

– E4 visualize the current status as follows: 

 

 

If the red LED (ON) is lit, communication is possible on the corresponding Ethernet interface. 
(relay closed) 

 

If  the  green  LED  (OFF)  is  lit,  communication  is  not  possible  on  the  corresponding  Ethernet 
interface. (relay open) 

 

If  the  orange  LED  (REMOTE)  is  lit,  the  software  determines  whether  communication  via  the 
corresponding  Ethernet  interface  is  possible.  The  status  LED  for  ON  or  OFF  lights  up 
accordingly. 

 
If no ON or OFF status LED lights up for a connection, for example "E2", the connection is not ready 
(possibly nothing connected). 
 

 

Summary of Contents for SEC3ER

Page 1: ...emberg Germany Edition June 2021 Version 1 0 Phone Fax Internet E mail 49 911 18 07 91 0 49 911 18 07 91 10 https www ipcomm de info ipcomm de SEC3ER 4 Port Ethernet Line Breaker General Operating Mai...

Page 2: ...4 Hardware Components 6 2 4 1 Mainboard 6 2 4 2 RS 232 RS 422 RS 485 Interfaces 6 2 4 3 Network Interfaces ETH0 ETH1 6 2 4 4 Ethernet Relays E1 E4 7 2 4 5 I O Interfaces 7 2 4 6 Flash Mass Storage 8...

Page 3: ...protection of your data and equipment against external influences We will be pleased to draw up a non binding offer for you Finally we want to draw your attention to the fact that any warranties will...

Page 4: ...on on all interfaces min 48 hours Communication disruptions transmission errors and every important component with regard to function temperature voltages etc are monitored Hundreds of restarts are ex...

Page 5: ...ontrol their communication state ON Manually switched on REMOTE Control via Software OFF Manually switched off In the switch position REMOTE software control is possible via a communication protocol o...

Page 6: ...s a RS 232 RS 422 RS 485 interface by the software SERIAL PORT RJ45 female connector Pin RS 232 RS 422 RS 485 1 DSR 2 RTS TXD Data 3 GND GND GND 4 TXD TXD Data 5 RXD RXD 6 DCD RXD 7 CTS 8 DTR Figure 4...

Page 7: ...y interface pair 2 4 5 I O Interfaces The embedded controller features eight digital inputs and eight digital outputs The digital inputs are equipped with overvoltage protection Digital input 9 pin mu...

Page 8: ...ts real time clock is buffered by a battery The durable lithium battery generally offers a lifespan of more than 5 years The default settings are designed in a way that the gateway can operate without...

Page 9: ...9 rack 3 Unscrew and lift the housing cover by loosening the corresponding nine screws It is recommended to use a Torx screwdriver of size T10 4 Pull the old battery out of the battery holder 5 When i...

Page 10: ...e is supplied with voltage The USR LED is freely configurable An imaginable function would be to display a particular connection status or more than one as an overall status 3 1 CPU LED The CPU LED vi...

Page 11: ...is lit communication is possible on the corresponding Ethernet interface relay closed If the green LED OFF is lit communication is not possible on the corresponding Ethernet interface relay open If th...

Page 12: ...gure 13 LEDs for digital inputs When the input level high is reached the input diagnostic LEDs DI 1 to DI 8 light up green 3 3 2 Digital Outputs Figure 14 LEDs for digital outputs If a digital output...

Page 13: ...Data Sheet A technical data sheet for the individual hardware models is available separately to this document In addition to pure technical data the document also contains information on approval and...

Page 14: ...remberg All rights reserved Germany 5 EU Declaration of Conformity An EU Declaration of Conformity for the individual hardware models is available separately for this document A current version of the...

Page 15: ...ration Power supply Value Description A 85 264 V AC E 9 60 V DC F 9 60 V DC EMV IEC 61850 3 RAM Flash Value Description A 256 MB 512 MB Flash Model Value Description A SEC3 The base model B SEC3PB The...

Page 16: ...on 1 0 IPCOMM GmbH 16 SEC3ER Manual Walter Bouhon Strasse 4 Copyright IPCOMM GmbH 2021 90427 Nuremberg All rights reserved Germany 7 SEC3ER Dimensions Figure 15 Dimensions front view SEC3ER Figure 16...

Reviews: