INTRODUCTION/GENERAL
WARNINGS/SAFETY
________________________________________________________________________________
p. 7 of 14
PREPARING THE BATTERY CHARGER
If you wish to use a battery charger not supplied with the machine, the connector sent with the
machine must be fitted on it. For installation of the connector, proceed as follows:
-
remove approx. 13 mm of protective sheath from the red and black cables of the battery
charger;
-
insert the cables in the connector ends and press with suitable crimping pliers;
-
insert the cables into the connector observing the polarities (red cable + black cable - ).
FITTING THE DISC BRUSHES
Raise the machine side apertures on both sides
and position the brushes below the compartment
ensuring that they rest against the stops to align
them with the engagement unit.
Insert the key into the panel, turn clockwise and
wait for the battery voltage indication to appear
on the display.
Press key N°8. The machine will firstly perform
a release operation (indicator A blinking),
enabling the engagement operation immediately
afterwards (indicator B blinking).
The machine is now ready for engagement of the
brushes which can be performed by pressing key
N°8 again. After pressing key 8 a second time,
the indicator B will remain on, blinking until the
engagement operation has been completed.