LEV.6: pump active with work cycle 100%
Auto: pump active according to drive work cycle
Up to 16% of speed, pump active 18%
Up to 32% of speed, pump active 36%
Up to 50% of speed, pump active 45%
Up to 65% of speed, pump active 60%
Up to 80% of speed, pump active 75%
Over 80% of speed, pump active 100%
The parameter can be changed via the buttons “-“ and “+”. When the display button is pressed
briefly, the setting is stored and you go on to the next page.
6.P1: Work speed: maximum drive speed. The parameter can be varied between 010 and 100 . The
parameter can be reduced by pressing the button “-“ and increased by pressing the button “+”.
When the display button is pressed briefly, the setting is stored and you go on to the next page.
7.P1: POWER OFF enable: ON or OFF. The parameter can be changed via the buttons “-“ and “+”.
When the display button is pressed briefly, the setting is stored and you go on to the next page.
For P2 and P3 the same procedure as the one above is used.
MAINTENANCE
Battery check and recharging
Periodically check the level of the electrolyte inside the battery. The battery compartment is below
the operator’s seat; raise the battery compartment cover and open the cell plugs: when necessary fill
the cells using distilled water; sulphuric acid solution must be used only the first time the battery is
activated dry.
Exercise extreme caution: the battery liquid is corrosive; if it comes into contact with the skin or
eyes, wash with plenty of water and seek medical advice.
After filling, close the cells with the plugs and clean the upper surface.
When necessary, recharge the battery following the instructions below:
-
Recharging must be performed in a well-ventilated area
-
Switch the machine off via the main key
-
Open the battery compartment and disconnect the machine battery connector; open all the
covers of the 18 battery cells (or elements)
-
Connect the battery connector to the battery charger
-
Connect the battery charger to the mains (the mains voltage and frequency must be equal to
the corresponding values applicable to the battery charger)