INTRODUCTION/GENERAL 
WARNINGS/SAFETY 
________________________________________________________________________________ 

p. 12 of 14 

 
LEV.6: pump active with work cycle 100% 

 

 
Auto: 
pump active according to drive work cycle  
 
Up to 16% of speed, pump active 18% 
Up to 32% of speed, pump active 36% 
Up to 50% of speed, pump active 45% 
Up to 65% of speed, pump active 60% 
Up to 80% of speed, pump active 75% 
Over 80% of speed, pump active 100% 

The  parameter  can  be  changed  via  the  buttons  “-“  and  “+”.  When  the  display  button  is  pressed 
briefly, the setting is stored and you go on to the next page. 

 

6.P1: Work speed: maximum drive speed. The parameter can be varied between 010 and 100 . The 

parameter  can  be  reduced  by  pressing  the  button  “-“  and  increased  by  pressing  the  button    “+”. 
When the display button is pressed briefly, the setting is stored and you go on to the next page. 

 

7.P1: POWER OFF enable: ON or OFF. The parameter can be changed via the buttons “-“ and “+”. 

When the display button is pressed briefly, the setting is stored and you go on to the next page. 

 
For P2 and P3 the same procedure as the one above is used.  
 
  

 
 
MAINTENANCE 
 
 
Battery check and recharging  
 
Periodically check the level of the electrolyte inside the battery. The battery compartment is below 
the operator’s seat; raise the battery compartment cover and open the cell plugs: when necessary fill 
the cells using distilled water; sulphuric acid solution must be used only the first time the battery is 
activated dry.  
 
Exercise  extreme  caution:  the  battery  liquid  is  corrosive;  if  it  comes  into  contact  with  the  skin  or 
eyes, wash with plenty of water and seek medical advice.  
 
After filling, close the cells with the plugs and clean the upper surface.  
 
When necessary, recharge the battery following the instructions below: 
 

-

 

Recharging must be performed in a well-ventilated area 

-

 

Switch the machine off via the main key  

-

 

Open  the  battery  compartment  and  disconnect  the  machine  battery  connector;  open  all  the 
covers of the 18 battery cells (or elements)  

-

 

Connect the battery connector to the battery charger 

-

 

Connect the battery charger to the mains (the mains voltage and frequency must be equal to 
the corresponding values applicable to the battery charger)  

https://harrissupplyind.com - To Order Parts Call 608-268-8080

Summary of Contents for CT160 700

Page 1: ...OPERATIONS MANUAL CT160 h t t p s h a r r i s s u p p l y i n d c o m T o O r d e r P a r t s C a l l 6 0 8 2 6 8 8 0 8 0...

Page 2: ...um gradient Bar code with serial number Manufacturer identification TABLE OF CONTENTS INTRODUCTION GENERAL WARNINGS SAFETY 2 UNPACKING 3 TECHNICAL SPECIFICATIONS 4 DESCRIPTION OF COMMANDS AND CONTROL...

Page 3: ...C The optimal working temperature must be between 0 C and 40 C The humidity must be between 30 and 95 Do not use the machine in an explosive atmosphere Do not use the machine as a means of transport D...

Page 4: ...a firm at work or during transfer are caused by failure to observe the most elementary safety rules A careful cautious user is the best guarantee against accidents and is more effective than any preve...

Page 5: ...1600 2100 1600 2100 1600 2100 Cleaning solution automatic metering YES YES YES YES Safety code display Voltmeter YES YES YES YES Maximum gradient 16 16 16 16 Drive motor power W 560 560 560 560 Forwar...

Page 6: ...5 Suction motor ON OFF 6 Recovery tank overflow level indicator 7 No cleaning solution indicator 8 Brush engagement release key not used in mod with roller head 9 Work program selection keys and indi...

Page 7: ...ow be performed before operating the machine for this operation follow the directions in the relevant paragraph BATTERIES installation and connection Make sure that you fit only terminals marked with...

Page 8: ...THE DISC BRUSHES Raise the machine side apertures on both sides and position the brushes below the compartment ensuring that they rest against the stops to align them with the engagement unit Insert...

Page 9: ...he support as shown in the figure Connect the suction pipe to the squeegee The squeegee blades scrape the film of water and detergent thus permitting perfect drying In the long term the continuous fri...

Page 10: ...cally disables all the functions except for the drive when the battery drops to a voltage of approx 29 volts indicating firstly battery low and then battery flat on the display In this case proceed wi...

Page 11: ...ll automatically raise the squeegee and only once this has been done will the consent be given for operation Use of reverse gear is identified by a safety buzzer all the functions will remain active T...

Page 12: ...le ON or OFF The parameter can be changed via the usual buttons and When the display button is pressed briefly the setting is stored and you go on to the next page 3 P1 Brush working pressure from 010...

Page 13: ...same procedure as the one above is used MAINTENANCE Battery check and recharging Periodically check the level of the electrolyte inside the battery The battery compartment is below the operator s sea...

Page 14: ...ps in reverse order ROUTINE MAINTENANCE SUMMARY TABLE Caution operation to be performed with the machine switched off and the key removed All routine or extraordinary maintenance operations must be pe...

Page 15: ...RTRT00250 c replace the main card MECE00265 and the control panel MEQE00050 a pedal in pushed before key turning ON a release the pedal a the plug under the pedal bad connected a check and tight the...

Page 16: ...tank and fill the solution tank b solution tank level sensor is blocked in lower position b check the sensor and eventually replace it code MECI00516 a is more than 5 minutes that the solution tank l...

Reviews: