The machine is provided with some safety functions.
Cut-in of the safety functions is shown via descriptions on the display (see table below) that facilitate identification of the faults or possible failures.
ref.
DISPLAY ERROR CODE
BRUSH
VACUUM
TRACTION
ERROR SOURCE
CAUSE
REMEDY
a- main board failure
a- replace the main board MECE00265 ;if control panel
release is < 1.26, replace the control panel MEQE00050 too
a- machine worked too much in a ramp
a- wait
≈
30' that the traction wheel temperature go down
b- the motor current consumption
b- if current is > 18A replace the tration motor RTRT00250
c- the motor thermal sensor
c- if at ambient temperature is open, replace it, METK00026
a- machine worked too much in a ramp
a- wait
≈
30' that the main board temperature go down
b- the motor current consumption
b- if current is > 18A replace the tration motor RTRT00250
c- replace the main card MECE00265 and the control panel
MEQE00050
a- pedal in pushed before key turning ON
a- release the pedal
a- the plug under the pedal bad connected
a- check and tight the plug
b- the potentimeter is broken
b- replace the potentiometer (see service bulletin 20060047)
a- machine worked too much at high pressure
a- wait
≈
30' that the main board temperature go down
b- the working program is to heavy for the floor
b- pass from P3 to P2 or P1 ( if already P1 use the
programming instruction to check the pressure value setted )
c- electronics faulty
c- replace the main card MECE00265 and the control panel
MEQE00050
a- battery voltage is
≤
31.5V
a- expect to charge the battery
OFF
accelerator pedal
potentiometer
5
TRACTION POTENTIOMETER
OFF
OFF
OFF
main board
temperature
sensor > 85°C
OFF
4
KEY ACCELERATOR
SEQUENCE
OFF
OFF
OFF
1
accelerator pedal
microswitch and
potentiometr
3
TRACTION TEMPERATURE
PAUSE
OFF
OFF
main board
OFF
2
MOTOR TEMPERATURE
PAUSE
OFF
OFF
traction motor
temperature
sensor > 95°C
OFF
ON
TRACTION PROBLEM
OFF
OFF
ON
main board
temperature
sensor > 85°C
7
BATTERY LOW
ON
ON
ON
battery
6
BRUSH TEMPERATURE
PAUSE