OPERATION
The fan draws moist air through the
refrigerated surface which cools it below
it’s dew point, removing moisture which
is collected and lead away. The cool air
then passes over the hot condenser,
where it is reheated. With the addition of
the other radiated heat the air is
discharged into the room at a higher
temperature but a lower relative humidity
than when the air entered the unit.
Continuous circulation of the room air
though the dehumidifier unit gradually
reduces the relative humidity in the
room.
The BD70 Industrial humidifier is a
robust, compact unit designed to control
the humidity in the enclosed space in
which it is placed.
The unit is thermally protected and will
switch off for a period if the maximum
operating temperature of 35°C is
exceeded.
MAINS PLUG WIRING
INFORMATION FOR EBAC
INDUSTRIAL
DEHUMIDIFIERS
IMPORTANT
The wires in the mains lead are coloured
and must be connected as shown in the
diagrams above by a qualified electrician.
ELECTRICAL CONNECTIONS
The wire which is coloured Green and
Yellow must be connected to the terminal
marked E or by the Earth Symbol. The
wire which is coloured Blue must be
connected to the terminal in the plug
which is marked with the letters N or
coloured Black. The wire which is
coloured Brown must be connected to the
terminal which is marked with the letter L
or coloured Red.
CHANGING THE FUSE
13 amp fuses that are ASTA approved to
BS1362 should only be used.