UNPACKING 

 
Thank  you  for  deciding  to  purchase  an 
Ebac  Industrial  dehumidifier.    Like  the 
many  tens  of  thousands  of  people  who 
have 

already 

bought 

an 

Ebac 

dehumidifier  we  are  confident  you  will 
find it is the most effective answer to the 
problem  of  condensation  and  dampness 
related problems 
 

IMPORTANT

 

 
Your  Industrial dehumidifier is packed in 
a plastic wrapping – please ensure that it 
is disposed of safely and where it will not 
be a danger to children. 
 

INTRODUCTION 

 

Carefully  remove  the  BD70  dehumidifier 
unit  from  it’s  transit  box  and  visually 
check for any signs of transit damage.  If 
there  is  evidence  of  damage  DO  NOT 
attempt  to  operate  the  unit,  call  your 
supplier  for  advice. 

  Retain  the 

packaging for further use, or dispose of it 
considerately. 
 
This  user  manual  tells  you  how  to  use 
the  BD70  dehumidifier.    Please  read  it 
thoroughly 

before 

operating 

the 

dehumidifier.    If  you  have  any  questions 
about  the  unit  please  contact  our 
Customer  Service  Department  at  the 
address  shown  at  the  back  of  this 
section or phone 01388 664400. 
 
Dehumidifiers  remove  moisture  from  the 
air circulating through it. 
 
Continuous 

operation 

reduces 

the 

relative humidity of the air and this helps 
prevent  rust,  rot,  mould,  mildew  and 
condensation  within  the  room,  or  other 
enclosed  space  where  the  dehumidifier 
is used. 

 

A  dehumidifier  consists  of  a  motor  – 
compressor 

unit, 

refrigerant 

condenser,  an  air  circulating  fan,  a 
refrigerated 

surface, 

means 

of 

collecting 

and 

disposing 

of 

the 

condensed  moisture  and  a  cabinet  to 
house these components. 
 

GENERAL 

 

Ebac  industrial  dehumidifiers  can  be 
stored  and  transported  in  the  horizontal 
or  vertical  position.    To  operate,  stand 
the  unit  upright,  connect  power  and  it  is 
ready for operation. 
 
When  a  generator  is  used  to  supply  the 
power,  it  is  essential  to  check  the 
minimum  kva  required  in  the  technical 
section  within  this  manual.    The 
generator  must  be  started  before 
connection is made to the dehumidifier. 
 

Summary of Contents for BD70

Page 1: ...avent Adremit Limited Unit 5a Commercial Yard Settle North Yorkshire BD24 9RH Get In Touch Call 0845 6880112 Email info adremit co uk BD70 INDUSTRIAL DEHUMIDIFIER USER MANUAL Drawing No TPC323 Issue 5...

Page 2: ...se the BD70 dehumidifier Please read it thoroughly before operating the dehumidifier If you have any questions about the unit please contact our Customer Service Department at the address shown at the...

Page 3: ...fier is a robust compact unit designed to control the humidity in the enclosed space in which it is placed The unit is thermally protected and will switch off for a period if the maximum operating tem...

Page 4: ...ed away correctly and not allowed to spill Any spillage will evaporate and will therefore have to be recycled through the dryer again which in effect only prolongs the drying period PORTABLE CONTAINER...

Page 5: ...he compressor is diverted into the evaporator coil where it melts the ice which has formed on the evaporator coil DUAL VOLTAGE MODELS The BD70 dehumidifier unit is fitted with a transformer which will...

Page 6: ...EFORE ATTEMPTING TO POWER THE UNNIT DUAL VOLTAGE UNNITS ONLY DO USE A RESIDUAL CURRENT DEVICE RCD WHERE POSSIBLE SERVICE The machine should be services by qualified Ebac personnel or other persons hav...

Page 7: ...4 5 Maximum Extraction 20 20 Noise Level Less than 50dba when running Finish Epoxy Coated Zintec Steel Mobility Light in construction and easily positioned Normal Rated Extraction at 15 C 65 RH Condit...

Page 8: ...involved Children shall not play with the appliance Cleaning and user maintenance shall not be made by children without supervision If the SUPPLY CORD is damaged it must be replaced by the manufacture...

Page 9: ...n circuit under no circumstances must direct heat be applied to the evaporator coil in an attempt to remove the build up of ice No attempt should be made to cut open any part of the refrigeration circ...

Page 10: ...Our Address Puravent Adremit Limited Unit 5a Commercial Yard Settle North Yorkshire BD24 9RH Get In Touch Call 0845 6880112 Email info adremit co uk...

Page 11: ...Our Address Puravent Adremit Limited Unit 5a Commercial Yard Settle North Yorkshire BD24 9RH Get In Touch Call 0845 6880112 Email info adremit co uk...

Page 12: ...4 9AD Tel 44 0 1388 664400 Fax 44 0 1388 662590 www eipl co uk sales eipl co uk American Sales Office Ebac Industrial Products Inc 700 Thimble Shoals Blvd Suite 109 Newport News Virginia 23606 2575 US...

Reviews: