TROUBLESHOOTING 

 
 
 

S

YMPTOM

 

C

AUSE

 

R

EMEDY

 

Unit inoperative  

1.  No power to unit 

1.  Check the power from the 
power supply panel 

Little or no airflow 

1. Loose fan on shaft 
2. Fan motor burnt out 
3. Dirty refrigeration coils 
4. Loose electrical wiring 

1. Tighten fan 
2. Replace the fan motor 
3. See 

Routine Maintenance

  

Section 
4. Check the wiring diagram 
to find fault and repair 

Little or no water 
extraction 

1. Insufficient air movement 
2. Compressor fault 
3. Loss of refrigerant gas 
4.  Blocked filter dryer 

1. Check all of the above 
2. Contact the Factory 
Service Center 
3. Contact the Factory 
Service Center 
4.  Contact the Factory 
Service Center 

Unit vibrates 
excessively 

1.  Loose compressor 
2.  Damaged fan 

1.  Tighten the nuts on the 
compressor mounts 
2.  Replace fan 

Water flooding inside 
the machine 

1. Drain pipe blocked/frozen 
2.  Drain pipe too high 

1.  Clear the obstruction, 
straighten or replace 
2.  No section of the drainage 
pipe 

 

Summary of Contents for 10146BR-US

Page 1: ...Page 1 of 16 Drawing TPC572 Issue 1 Date 08 02 22 CD425 10146BR US INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL www eipl co uk...

Page 2: ...e 2 of 16 Drawing TPC572 Issue 1 Date 08 02 22 CD425 PACKAGE CONTENTS Item Description Quantity 10146BR US Dehumidifier 1 3086119 Jubilee clip 2 3014315 Reinforced tubing 16mm I D 2 X 3M TPC572 Manual...

Page 3: ...n tray for collecting and disposing of condensed moisture f A cabinet to house the above components The fan draws the moist air through the evaporator coils which cools the air below its dew point Moi...

Page 4: ...igerants used in products manufactured by Ebac Industrial Products Ltd is as follows R134a 1300 R407c 1610 For type and weight of refrigerant contained in this unit please refer to the product data la...

Page 5: ...the CD425 s drain tray Failure to observe this requirement will result in internal flooding of the dehumidifier POSITIONING The CD425 is designed for indoor use only Position the dehumidifier unit in...

Page 6: ...lows out of the top of the machine 3 Check dehumidification process a Remove front cover b Check actual relative humidity inside the area c Set humidity control to a lower value than the actual relati...

Page 7: ...sed water should cover the entire evaporator coil 4 Leave the unit to run for approximately 42minutes from compressor starting after which the unit should go through a 4 minute defrost cycle During th...

Page 8: ...covered with droplets of water rather than frost Partial frosting accompanied by frosting of the thin capillary tubes indicates loss of refrigerant gas or low charge 4 Check all wiring connections 5...

Page 9: ...he refrigerant compressor The charging stub should be crimped and rebrazed after servicing NEVER allow permanent service valves to be fitted to any part of the circuit Service valves may leak causing...

Page 10: ...g diagram to find fault and repair Little or no water extraction 1 Insufficient air movement 2 Compressor fault 3 Loss of refrigerant gas 4 Blocked filter dryer 1 Check all of the above 2 Contact the...

Page 11: ...020835 1 Filter Dryer 3020930 1 Fan Motor 3030140 1 Contactor Fan 3030301 1 Contactor Compressor 3030321 1 Auxiliary contact Fan 3030322 1 Solenoid Coil 3030454 1 Transformer 3031144 1 Terminal Block...

Page 12: ...WRITTEN OR IMPLIED WARRANTY WITH RESPECT TO THE FOREGOING DESCRIBED MERCHANDISE For Your Records Model ____________________ S N ______________________ Date Received ______________ SAVE THIS SECTION FO...

Page 13: ...d This product contains fluorinated greenhouse gases covered by the Kyoto Protocol The refrigeration system is hermetically sealed The Global Warming Potential GWP of refrigerants used in products man...

Page 14: ...Page 14 of 16 Drawing TPC572 Issue 1 Date 08 02 22...

Page 15: ...Page 15 of 16 Drawing TPC572 Issue 1 Date 08 02 22...

Page 16: ...state Bishop Auckland County Durham DL14 9AD Tel 44 0 1388 664400 Fax 44 0 1388 662590 www eipl co uk sales eipl co uk American Sales Office Ebac Industrial Products Inc 700 Thimble Shoals Blvd Suite...

Reviews: