IP Enclosures IP-ACOWM085 User Manual Download Page 13

Designation: AIR CONDITIONER FOR ELECTRICAL ENCLOSURE

 

Page 13/16

 

UMA-CDZ-IP-ACOWM085-00

 

WARRANTY 

 

WE 

IP ENCLOSURES 

 

 

 

 

guarantees that the product is free from any quality defects. 

The product is guaranteed for a period of 12 months from the date of delivery, provided it 
operates under the following conditions: 

1.  value of power supply indicated in the data plate is completely respected; 
2.  requirements specified on user’s manual are completely respected; 
3.  cabinet temperature is not higher or lower than its rated temperature; 
4.  ambient temperature is not higher or lower than its rated temperature; 
5.  the product is mounted on cabinets with a minimum IP54 protection level; 
6.  the product is mounted on cabinets that not requiring higher cooling power than 

expected; 

7.  the product is clearly identifiable by serial number. 

 
The warranty does not apply if : 

1.  the cooling circuit has been modified about type and quantity of refrigerant or 

composition; 

2.  the unit operates in acid or corrosive ambient; 
3.  the unit has been modified without IP ENCLOSURES consent. 

 

This warranty shall become null as soon as the product is altered or modified in its 
structure or in circuits. 
The terms of this warranty (commencement and termination dates) are not modified by 
any repair or replacement of products. 
For every part that results defective during the period of this warranty, IP ENCLOSURES 
shall repair or replace it. Any others charges arising from removal, handling and 
installation of the products shall not be refunded by IP ENCLOSURES. 
Like is specified on user’s manual, installation, handling, the correct earthing in 
accordance with all current standards are under the responsibility of costumer. 
In the event of any damage caused by a defective product shall apply the EEC85.374 
standard. 
The malfunction must be communicated in writing to IP ENCLOSURES. 
Warranty is void if the costumer is not in good standing with the payments 

 
 
 

 
 
 
 

 
 
 

Summary of Contents for IP-ACOWM085

Page 1: ...00 USER S MANUAL PART 2 AIR CONDITIONER FOR ELECTRICAL ENCLOSURE OUTDOOR APPLICATION IP ACOWM085 IP ACOWM085 0X Document UMA CDZ IP ACOWM085 00 Date Name Description Original user s manual for air con...

Page 2: ...closure there must not be components that could affect the proper ventilation Provide a proper fixing of the electrical enclosure to the floor to prevent accidental tipping due to the supplementary we...

Page 3: ...IP ACOWM085 0X FEATURES Unit Power supply V ph Hz 230 1 50 60 Cooling capacity EN14511 A35 A35 W 850 900 A35 A50 W 625 650 Absorbed electric power EN14511 A35 A35 W 490 530 A35 A50 W 600 640 Rated cu...

Page 4: ...ERAL CHECKS electrical enclosure must be disconnected form power supply electrical data shown on rating label pasted on air conditioner side must be guaranteed Electrical enclosure must be sized accor...

Page 5: ...IR CONDITIONER FOR ELECTRICAL ENCLOSURE Page 5 16 UMA CDZ IP ACOWM085 00 2 3 FITTING 1 Make the fixing hole on the enclosure as is shown in the drilling template Deburr all sharp edges to avoid accide...

Page 6: ...nscrewing included in mounting kit 5 Connect the condensate drain pipe like is shown in picture below Put some glue on aluminium pipe before to insert it Air conditioner produces condensate because th...

Page 7: ...ush the spring with a screwdriver and then insert the wire 2 Check the proper wire insertion 3 Connect the unit with the power supply Electrical data shown on rating label pasted on air conditioner si...

Page 8: ...Designation AIR CONDITIONER FOR ELECTRICAL ENCLOSURE Page 8 16 UMA CDZ IP ACOWM085 00 3 1 WIRING DIAGRAM 3 1 1 IP ACOWM085 IP ACOWM085 0X...

Page 9: ...minimum interval of two successive switch on of the compressor parameter C2 is elapsed Condenser fan turns ON when refrigerant pressure rises up to pressure switch set Compressor and condenser fan tur...

Page 10: ...ide 0 60 40 min U1 Select temperature display sensor 1 00 display cabinet sensor 01 display evaporator sensor 0 U2 Switch between Fahrenheit and Celsius 3 00 Fahrenheit 01 Celsius 01 U3 Select defrost...

Page 11: ...er selecting the menu press Set to enter the current menu and set its parameters Use or to adjust parameter values then press Set again to return to menu selection status 5 Under any parameter setting...

Page 12: ...rH when temperature A6 and alarm delay time run out controller will display rH rL when temperature A5 and alarm delay time run out controller will display rL 5 SPARE PARTS LIST REFERRED TO WIRING DIA...

Page 13: ...oling circuit has been modified about type and quantity of refrigerant or composition 2 the unit operates in acid or corrosive ambient 3 the unit has been modified without IP ENCLOSURES consent This w...

Page 14: ...E LOW VOLTAGE DIRECTIVE 26 February 2014 2014 30 UE EMC DIRECTIVE 26 February 2014 2011 65 UE ROHS DIRECTIVE 8 June 2011 STANDARDS APPLIED TO MEET THE PRINCIPAL ELEMENTS OF THE DIRECTIVE EN 60335 2 40...

Page 15: ...Designation AIR CONDITIONER FOR ELECTRICAL ENCLOSURE Page 15 16 UMA CDZ IP ACOWM085 00 SAA CERTIFICATE...

Page 16: ...Designation AIR CONDITIONER FOR ELECTRICAL ENCLOSURE Page 16 16 UMA CDZ IP ACOWM085 00 NOTES...

Reviews: