![IOtech DaqBoard/3000 Series User Manual Download Page 90](http://html1.mh-extra.com/html/iotech/daqboard-3000-series/daqboard-3000-series_user-manual_2088005090.webp)
7-8 Specifications
988093
Note
: Specifications are subject to change without notice.
PDQ30 Type T Thermocouple
Typical Performance of 12 PDQ30 Units; 0°C
(Note 1)
-1.5
-1.0
-0.5
0.0
0.5
1.0
1.5
0
5
10
15
20
Channel
Erro
r ( °
C
)
Note 1: Assumes 16384 oversampling applied, CMV = 0.0V, 60 minute warm-up, still environment, and 25°C ambient temperature.
Excludes thermocouple error. TC
IN
= 0.0 °C
Accessories and Cables
Termination Board (TB-100)
:
Termination board with screw terminals for access to DaqBoard/3000 Series I/O.
The terminal board connects to the DaqBoard’s 68-pin connector via a CA-G55, CA-56, or CA-56-6 cable.
Rack Mount Kit (Rack3)
:
Kit for mounting the TB-100 termination board to a rack.
DBK215 Termination Module
:
Includes 16 BNC connectors and internal screw-terminals. DBK215 connects to
the DaqBoard’s 68-pin connector via a CA-G55, CA-56, or CA-56-6 cable.
PDQ30 Analog Input Expansion Module
: Adds 48 SE [or 24 DE] channels to a DaqBoard/3000 Series board.
Characteristics of the expansion channels are identical to those of the onboard channels. PDQ30 connects to
the 3000 Series board via HDMI cable CA-266-3, or CA-266-6.
PDQ30 cannot be connected to a
DaqBoard/3006.
CA-G55
:
68-conductor ribbon expansion cable. Can be used to connect a DaqBoard/3000 Series board to a
TB-100 or DBK215. Cable length: 3 ft.
CA-G56
:
68-conductor shielded expansion cable. Can be used to connect a DaqBoard/3000 Series board to a
TB-100 or DBK215. Cable length: 3 ft.
CA-G56-6
: 68-conductor shielded expansion cable. Can be used to connect a DaqBoard/3000 Series board to a
TB-100 or DBK215. Cable length: 6 ft.
CA-266-3
:
HDMI cable. Can be used to connect a PDQ30 expansion module to a DaqBoard/3000 Series board.
Cable length: 3 ft.
PDQ30 cannot be connected to a DaqBoard/3006.
CA-266-6
:
HDMI cable. Can be used to connect a PDQ30 expansion module to a DaqBoard/3000 Series board.
Cable length: 6 ft.
PDQ30 cannot be connected to a DaqBoard/3006.
Summary of Contents for DaqBoard/3000 Series
Page 2: ...ii...
Page 6: ...vi DaqBoard 3000 Series User s Manual...
Page 16: ...IG 8 DaqBoard Installation Guide 918494 1033 0940 rev 8 0...
Page 38: ...2 8 Connections Pinouts 918494 DaqBoard 3000 Series User s Manual...
Page 42: ...4 2 Calibration 918494 DaqBoard 3000 Series User s Manual...
Page 82: ...6 12 Setpoint Configuration for Output Control 908794 DaqBoard 3000 Series User s Manual...
Page 104: ...DBK215 pg A 14 948894 Appendix A...
Page 106: ...B 2 Hardware Analog Level Trigger 90794 Appendix B...