background image

iOptron Corp. | 6E Gill Street | Woburn, MA 01801 USA | (781) 569-0200 | www.iOptron.com

 

 

The  CEM120  has  a  Losmandy  D  dovetail  saddle,  as 
shown  below.  Release  the  dovetal  saddle  locking 
knobs  and  slide  the  telescope  dovatal  plate  into  the 
saddle. Tighten the saddle locking knob. 

 

5.

 

Balancing the Payload:  

After attaching the scope and 

accessories,  the  mount  head  assembly  must  be 
balanced  in  both  R.A.  and  DEC  axes  to  ensure 
minimum stresses on the mount driving mechanism. 

CAUTION:  The telescope may swing freely when the 
R.A.  or  DEC  during  the  balancing  process.  Always 
hold  on  to  the  mount  and/or  telescope  assembly 
before releasing the Axle Locking Knob and/or Gear 
Switches  to  prevent  it  from  swinging,  which  can 
cause personal injury and/or equipment damage. 

With  the  corresponding  Gear  Switch  disengaged, 
balance  in  DEC  axis  by  moving  the  scope  with 
accessories  back  and  forth  in  the  mount  saddle. 
Balance the assembly in R.A. axis by moving CW along 
its shaft. 

Only  balance  one  axis  at  a  time  and  start  with  the 
DEC axis first. Double check the mount to make sure 
both the RA and DEC axes are balanced.  

Return  the  mount  to  the  Zero  Position  after 
balancing;  i.e.,  the  CW  Shaft  points  to  ground,  and 
the telescope tip is at its highest position. 

6.

 

Connecting Cables:

  Plug in a 12V DC power supply to 

the  DC12V  POWER  socket.  Connect  the  Go2Nova

®

 

8407 Hand Controller to the HBX port on the mount 
side panel.  Install Wi‐Fi antenna (right angle one) and 
GPS antenna.  

 

Refer  to  the  full  User’s  Manual  on  how  to  use  the 
cable management system.

 

7.

 

Performing  Polar  Alignment:

    You  may  install  an 

optional  electronic  polar  scope,  with  an  optional 
polar scope adapter, for polar alignment. Or you may 
use polar alignment software to do the job.

 

You  may  also  use  “Polar  Iteration  Align”  in  hand 
controller for polar alignment. 

8.

 

Manual  Operation: 

The  mount  can  now  be  used  to 

observe  astronomical  objects  with  the  HC.  Unlock 
both RA and DEC Axle Locking Knob, and 

engage

 both 

RA and DEC Gear Switch, as shown n 

Fig.3

. Use arrow 

keys (

▼,

 and 

) to point the telescope to the 

desired  object.    Use  the  number  keys  to  change  the 
slewing  speed.  Press  the 

STOP/0

  button  to  start 

tracking. 

9.

 

Setting  Controller:

    Press  the 

MENU  button

;  then 

Settings

 

=> “

Set Time & Site

”.  

 

Enter the current date and check for Daylight Saving 
Time  using  arrow  and  number  keys.  Enter  the  time 
zone offset to the UTC; for examples: 

 

Boston is “UTC ‐300 minutes” 

 

Los Angeles is “UTC ‐480 minutes” 

 

Rome is “UTC +060 minutes” 

Summary of Contents for CEM120 7300

Page 1: ... HC controller cable 1X RS232 RJ9 serial cable 1X 12V5A AC adapter 100 240V 4X Base mounting screws 1X GPS external antenna 1X Wi Fi external antenna Quick Start Guide this document ONLINE RESOURCES at www iOptron com under Support User s Manual Tips for set up and using the products Hand controller and mount firmware upgrades check online for the latest version 1 The design and packaging may chan...

Page 2: ...o the RA won t swing and there is no force applied onto the worm ring gear Fig 2 During mount balancing process pull and turn the Axle Locking Knob to release it and leave the Gear Switch at disengaged position Now the mount will swing freely in RA direction Fig 3 During normal operation of the mount i e GOTO and tracking turn the Gear Switch to locking position to engage the worm ring gear while ...

Page 3: ...ter 1 4 turn with a 5mm Allen wrench Turn the Latitude Adjustment Knob until the arrow points to your current latitude on the Latitude Scale There are fine scales on the Knob as shown in the photo Tighten the Latitude Locking Clamps when done NOTE For those low latitude places between 0 to 10 special low latitude CWs 7326LL are needed Please specify when order 4 Installing the Counterweight s and ...

Page 4: ...o the Zero Position after balancing i e the CW Shaft points to ground and the telescope tip is at its highest position 6 Connecting Cables Plug in a 12V DC power supply to the DC12V POWER socket Connect the Go2Nova 8407 Hand Controller to the HBX port on the mount side panel Install Wi Fi antenna right angle one and GPS antenna Refer to the full User s Manual on how to use the cable management sys...

Page 5: ...he GOTO accuracy refer to the full User s Manual for more details 12 Go to an Object The mount is now ready for GOTO and tracking targets Press MENU select and ENTER Select and Slew Select a category for example Solar System then select an object of interest for example Moon Press ENTER and the telescope will slew to the object and automatically start tracking 13 Sync to Target If the object is no...

Page 6: ...duct has been modified in design or function or subjected to abuse misuse mishandling or unauthorized repair Further product malfunction or deterioration due to normal wear is not covered by this warranty IOPTRON DISCLAIMS ANY WARRANTIES EXPRESS OR IMPLIED WHETHER OF MERCHANTABILITY OF FITNESS FOR A PARTICULAR USE EXCEPT AS EXPRESSLY SET FORTH HERE THE SOLE OBLIGATION OF IOPTRON UNDER THIS LIMITED...