background image

Quick Start Guide

MB-TP12 

Universal VESA Mounting Box for 12" Modero Panels

The MB-TP12 Universal VESA Mounting Kit (

FG031-50

) allows the 12" Modero 

touch panels to be mounted on a pivot/pitch, extendable arm, pole, ceiling, 
under-cabinet mount, or any other variation of VESA-compliant mounting 
hardware.

The MB-TP12 kit includes everything the installer needs to mount a 12” Modero 
panel (wall mount version) to any standard 75mm x 75mm VESA mounting 
hardware (purchased separately). The kit includes a metal back box, a plastic 
rear cover (with cable routing hole (which accepts the included strain-relief 
grommet) and other required hardware (see Specifications table for details). .

 

Specifications 

Overview - Installing the MB-TP12 Kit 

Upgrading the original Modero back box with the MB-TP12 Universal VESA 
Mounting Kit involves three main processes:

Removing the original Modero back box, and installing the new 

MB-TP12 back box.

Threading cables through the strain relief grommet opening in the rear 

plastic cover.

Finalizing the installation of the NXD (with MB-TP12 back box and 

cables) into the plastic cover, securing both components, and finalizing 
the strain relief grommet installation.

Removing the Original Modero Back Box

1.

Detach all connectors from the side of the touch panel.

2.

Remove the magnetic faceplate from the NXD unit by carefully grip-
ping the faceplate and pulling outwards.

3.

Place the LCD face-down on a soft cloth to expose the bottom of the 
panel and prevent scratching of the LCD.

4.

Using a grounded Phillips-head screwdriver, remove the two screws 
on either side of the metal connector overlay, and remove the head-
phone nut from the headphone jack. 

5.

Remove the Connector Overlay from the back box housing.

6.

Remove the four pan-head housing screws from the rear of the NXD 
unit (FIG. 2). These screws secure the back box to the internal panel 
casing.  

7.

Lift the back box housing to separate it from the internal panel casing.

Note

:

 

Do not remove the four panel securing screws.

 These screws secure the 

LCD to the metal casing.

Installing the MP-TP12 Back Box

1.

Unscrew the four pan-head Housing screws (#8-32) from the 
MP-TP12 rear plastic cover.

2.

Gently place the MP-TP12 back box over the internal panel casing 
(with the cable routing hole on the right-side of the panel).

3.

Re-install and secure the four pan-head Housing screws into their pre-
drilled holes along the edges of the MB-TP12 back box (FIG. 2) and 
secure them using a grounded Phillips-head screwdriver.

4.

Replace the Connector Overlay back over the connector opening and 
align the connector locations.

5.

Re-secure the metal connector overlay (using a grounded 
Phillips-head screwdriver) and re-secure the nut on the headphone 
jack.

Cable Installation for the MP-TP12 Back Box

1.

Connect the cable connectors (RJ-45, Ethernet, and any other 
audio/video wiring) to their respective locations on the side of the 
touch panel.

2.

Use the tie-wrap (45-0009A) to wrap the cables together inside the 
VESA Mount enclosure. This cable tie is used to insure the cable will 
not pull through or work itself through the new larger strain relief 
grommet (45-0032-01) over time.

3.

Thread the incoming cables through the hole on the rear plastic cover 
and then through the strain relief grommet.

4.

Slide the grommet along the cable and securely insert it into the 
opening on the rear plastic cover (FIG. 4).

Finalizing the Installation

1.

Gently place the rear plastic cover over the NXD panel (with LCD and 
MB-TP12 back box).

2.

Insert the protruding cables, coming out from the opening on the rear 
plastic cover, into the open strain relief grommet.

3.

Allow some slack/length on these cables as a service loop. This ser-
vice loop provides enough cable length so you can later remove the 
NXD (with connected cables) from the rear plastic cover.

FIG. 1  

MB-TP12 Universal VESA Mounting Box and Rear Cover (rear view)

MB-TP12 Specifications

MB-TP12 Mounting Kit -
Installed Dimensions 
(HWD):

• 12.37" x 12.58" x 3.52" (31.42 cm x 31.95 cm x 8.94 cm)

Operating /Storage
 Environments:

• Operating Temperature: 0° C (32° F) to 40° C (104° F)
• Operating Humidity: 20% - 85% RH
• Storage Temperature: -20° C (-4° F) to 60° C (140° F)
• Storage Humidity: 5% - 85% RH

Included Accessories

• Black metallic VESA back box (62-0031-50)
• Black plastic cover (with grommet opening) (60-0031-50)
• Four Phillips pan-head screws (#8-32 x 0.50 Black) 

(80-0146-02)

• Tie  Wrap  (

Large

) (45-0009A) (

for use with NXA-MTC/RGB

)

• Twelve Under-cut Phillips-head screws (#6-32 x 0.500 Black)

(80-0139)

• Strain relief grommet (45-0004-03) (

for use with CA2250-50

)

• Universal VESA Mount grommet (45-0032-01) 

 (

for use with NXA-MTC/RGB

)

75mm x 75mm
VESA mounting configuration

Cable routing hole
(accepts Strain Relief Grommet)

Vents

front

FIG. 2  

Location of the attachment screws on the NXD back box

Unscrew these

4 pan-head Housing 

DO NOT

REMOVE

these

(panel

securing)

screws

screws to remove the
back box

DO NOT

REMOVE

these

(panel

securing)

screws

Reviews: