IonWays RO System Installation & Service Manual Download Page 7

©Copyright 2009 IonWays, LLC VS.1 

Page 7 

 

 

 

Installation of IonWays UnderSink Kit (Optional

Included in your new under sink kit is: 

1.)  (1) Patent Pending double spouted faucet 
2.)  (1) Metal Cold Water Connector w/ Shut off  

     (Connect to Cold Water) ASVPP1 

3.)  (1) Alternate Color Faucet Base  
4.)  (1) Light Grey 90

o

 Fitting  

     (Connect to Acidic Spout) 

5.)  (1) Dark Grey Threaded Fitting  

  (Connect to Alkaline Spout) 

 
 
 
 
 
 
 
 
 
 
 

Attaching to cold water pipe: 

1.)  You will want to maintain access to the Control Panel on the ionizer. Place the ionizer close to the front of 

the cabinet. A template is included for installation on the cabinet wall if you desire.  

2.)  Attach the threaded fitting for the Alkaline Spout (see drawing above) into the top of your ionizer as a 

replacement for the flexible stainless steel tube. (Do not over-tighten, if needed use Teflon tape) 

3.)  Push the larger sized opening on the 90

o

 Acid Spout fitting onto the Acidic Water Outlet.  

4.)  Install the faucet into an existing hole, or by cutting an inch and a half hole in your counter top, or sink.  

(be sure that the faucet will clear the sink) 

5.) 

Turn off your cold water supply line

 

. Attach the cold water connecter to the cold water supply line. 

Hooking up the faucet: 

1.)  Drill 1 ½” hole in countertop if one does not already 

exist. Typically the hole for a soap dispenser can 
also be used.  

2.)  Install the faucet and base plate on top of counter  
3.)  One BLACK line goes to the Remineralizing 

Cartridge (Stage 4 in R/O diagram, page 3) 

4.)  The other BLACK one goes to the water inlet on the 

ionizer. The two black lines are interchangeable.   

5.)  The 

BLUE 

goes to the alkaline top spout. 

6.)  The 

RED 

goes to the acidic outlet. 

 
 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for RO System

Page 1: ...sis Drinking Water System Includes Remineralization System tested and certified by WQA against NSF NSI Standard 58 for the reduction of Arsenic Barium Copper Cyst Fluoride Hexavalent Chromium Lead Rad...

Page 2: ...valve feed water valve faucet assembly 5 Manual and warranties 6 Optional Undersink Kit Sold Separately Optional Under Sink Kit Sold Separately RECOMMENDED TOOLS LIST Variable speed drill 1 8 and 1 4...

Page 3: ...talled on top of the counter IonWays also offers an optional double spouted faucet that is fed from the ionizer installed under the sink If you are using the double spouted faucet do not use the blue...

Page 4: ...obium Osmium Palladium Potassium Praseodymium Rhenium Rhodium Rubidium Ruthenium Samarium Scandium Sodium Strontium Tantalum Tellurium Terbium Thallium Vanadium Yttrium Zirconium Fitting Installation...

Page 5: ...out of faucet with angle valve turned off the house main will have to be turned off Care must be taken for appliances that may be damaged by an interrupted water supply 2 Easy Connector Cold Water Sup...

Page 6: ...alve off Mounting the Drain Clamp The drain clamp VV DSP014 3 will fit most standard drain pipe 1 1 4 It should be installed above the trap and on the vertical tailpiece 1 Position the drain saddle in...

Page 7: ...r as a replacement for the flexible stainless steel tube Do not over tighten if needed use Teflon tape 3 Push the larger sized opening on the 90 o Acid Spout fitting onto the Acidic Water Outlet 4 Ins...

Page 8: ...ete 7 After the second tank is filled turn on the ionizer and allow it to purge by running it for one minute before getting a glass of water 8 Check for leaks daily for the first week and periodically...

Page 9: ...ains a replaceable treatment component critical for effective reduction of total dissolved solids The product water shall be tested periodically to verify that system is performing satisfactorily PERF...

Page 10: ...arsenic from water very well RO systems are very effective at removing pentavalent arsenic A free chlorine residual will rapidly convert trivalent arsenic to pentavalent arsenic Other water treatment...

Page 11: ...n fouling with sediment or scale or failure to operate the system in accordance with the instructions contained in the owner s manual 2 The following operating conditions must also be followed for thi...