7.4 1x1 Sequence HDMI Layout w/ Four IP Cameras
This quick setup guide assists you in quickly setting up the ION-R100 for use as a spot monitor
in 1x1 sequence output layout on an HDMI display for use with four IP cameras.
1.
Connect an HDMI cable between the ION-R100 and your HDMI display.
2.
Connect the ION-R100 to the PoE switch using a Cat5/6 network cable.
3.
The ION-R100 will power on (via PoE). Wait for the front status LED to turn green.
4.
Connect your workstation to the same network as the ION-R100.
5.
Launch the IonConfigTool on the workstation (found at
www.ionodes.com
).
6.
The IonConfigTool should discover and list the ION-R100.
7.
Apply the desired TCP/IP network parameters to the ION-R100 (static IP recommended).
8.
Open a web browser on the workstation at type in the IP address of the ION-R100.
9. Login to the ION-R100 web interface (default is admin:admin).
10. Navigate to the
Configuration / Video Out
configuration section.
11. Under the
General
sub-section:
a. Set the
Output Connector
to
HDMI.
b. Set the
Output Digital Format
to the desired resolution.
c. Set the
Output Layout
to
sequence
.
d. Set the desired
Sequence Order
and
Sequence Interval
.
12. Under
Decoder Selection
: