47
•
Serial Port 1
–
This section allows you to configure serial port parameters for the serial port 1, exposed
on connector J6 (pins 1-4). This serial port is intended for connection to a PTZ controller. Configure the
serial port settings to match the serial port settings of your PTZ controller.
Note:
The TCP port under Serial Port 1 allows the user to send data received on the Eth interface, on the
defined TCP port, directly to the serial port, without any alteration. If your application does not require
this functionality, there is the possibility of disabling it by unchecking the corresponding tick box.
•
Serial Port 1
Point to Point
–
This section allows you to configure a point to point serial port connection
for creating a persistent serial port connection with a network endpoint.
•
Serial Port 51
–
This section will only
appear if you have enabled the “
Use Transparent Port
” feature in
the Imaging > Digital Sensor Settings section in the Configuration menu. This serial port instance
represents the serial port connection between the encoder module and the camera sensor via the
corresponding video interface. This section allows you to configure the TCP port on which the encoder
module will accept transparent TCP connections
–
this connection allows external software / devices to
send command and control data directly to a camera sensor. When in Custom sensor mode, this section
will expose serial port settings to allow you to properly configure the serial port connection with your
custom camera sensor.
Summary of Contents for ATOMAS-MINI-DUAL
Page 1: ...ATOMAS MINI DUAL User Manual OEM Encoder Platform Document Version 2 3 ...
Page 30: ...30 support ionodes com https imaging ionodes com 1 450 696 1060 ...
Page 35: ...35 support ionodes com https imaging ionodes com 1 450 696 1060 ...
Page 42: ...42 support ionodes com https imaging ionodes com 1 450 696 1060 ...
Page 50: ...50 support ionodes com https imaging ionodes com 1 450 696 1060 8 5 Security ...