Unrivalled Detection.                              www.ionscience.com  

  

 
 
 
 

 

 
Instrument User Manual V1.4 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for TIGER LT

Page 1: ...Unrivalled Detection www ionscience com Instrument User Manual V1 4...

Page 2: ...g your Ion Science product The standard warranty of your instrument is one year however the warranty can be extended To extend the warranty to 2 years you must register your instrument online within o...

Page 3: ...batteries MN1500 BATTERY CONNECTION The PhoCheck Tigers lithium ion and alkaline battery packs have been specially designed to allow connection to the PhoCheck Tiger Instrument while in potentially ha...

Page 4: ...piles alcalines Duracell Procell MN1500 CONNEXION DES PILES DE LA BATTERIE Les batteries lithium ion et les piles alcalines du PhoCheck Tiger ont t sp cialement con ues pour permettre la connexion l i...

Page 5: ...326 1 2006 Electrical equipment for measurement control and laboratory use EMC requirements Group 1 Class B equipment emissions section only BS EN61326 1 2006 Electrical equipment for measurement cont...

Page 6: ...T 14 Tiger PC LT software instillation 17 Connecting TIGER LT to a PC 17 The Configuration Screen 20 Calibration 22 The Firmware Screen 23 Downloading Data Logged Readings 25 Software Disclaimers 27 B...

Page 7: ...vironments Filters are available from your distributor or at www ionscience com Quality Assurance TIGER LT has been manufactured in compliance with ISO9001 2008 which ensures that the equipment suppli...

Page 8: ...ency of use particularly with repeatable tasks TIGER PC LT PC Software maintains the intuitive look and feel by adopting the same graphical symbols TIGER PC also helps manage logged data files and mul...

Page 9: ...harge for use The battery icon see Understanding the display screen should show at least two full segments Rechargeable Batteries TIGER LT instruments leave the factory with the Rechargeable Battery P...

Page 10: ...ed as a switching operation A continuous press is used to adjust numbers or change gas selections by automatically rolling Keypad Function Descriptions Soft keys A and B rely on graphical prompts on t...

Page 11: ...e area between the soft key indicators displays the measurement units Status icon Memory Status This icon only appears if the instrument has the data logging functionality Four sections within the bor...

Page 12: ...rts the Bell and the sound bars When the instrument reaches a Low alarm the Bell and one sound bar will flash when a High alarm is reached the Bell and both sound bars flash Flashlight Torch When the...

Page 13: ...ear in the soft key areas as soft key options They are selected using the Up and Down keys Those labelled optional will only appear if your TIGER LT has that functionality These icons can be reorganis...

Page 14: ...viz Red LED s flash and audible alarm sounds This is done to alert the user to avoid accidental switch off Zeroing Pressing the Zero soft key presents two zero options selected with the Up or Down ke...

Page 15: ...T will operate against that calibration Readings taken against unsatisfactory calibrations may be unreliable Factory Calibration Not for operator use Return to Ion Science Ltd or your distributor for...

Page 16: ...tory calibration Date of Custom calibration 3rd Screen SPAN 1 gas concentration set in TIGER PC LT SPAN 2 gas concentration set in TIGER PC LT PID PID reading A D Digital number from PID 4th Screen IR...

Page 17: ...t and download logged data The software is available to download from the ion science website Once the software is downloaded from the website double click on the zip file and follow the installation...

Page 18: ...ill appear Note If while using this software your TIGER LT should inadvertently be turned off or disconnected from your computer click on Instrument s again and proceed as below 3 Switch TIGER LT on a...

Page 19: ...TIGER LT MANUAL Ion Science Ltd Page 19 of 41 Tiger PCLT software...

Page 20: ...software 5 This page gives the current status of your TIGER LT If the snapshot screen appears click Yes You can delete the snapshot later if you wish see TIGER PC LT Software The Configuration Screen...

Page 21: ...trument into sleep mode while it is connected to the PC software The instrument will awaken as soon as it is disconnected from the PC software Clock Select 24 or 12 hour format using the radial button...

Page 22: ...TIGER LT to vibrate under alarm conditions select the vibrate symbol Calibration Use this area to define your Custom Calibration parameters First connect TIGER LT to your PC as detailed above under Co...

Page 23: ...is not in an alarm condition and that no datalogging or Health and Safety readings are being collected Check that the battery pack is sufficiently charged at least two bars IMPORTANT The Firmware upgr...

Page 24: ...nect the TIGER LT at this point Please follow the next part before disconnecting the TIGER LT After the PC Software has completed sending the upgrade to the TIGER LT the instrument will then have to f...

Page 25: ...og screen and a list of the datalog sessions is presented Expand the datalog folder and select the session of interest Details of the data collected during that session are presented in numerical and...

Page 26: ...is in normal Survey mode is not in an alarm condition and that no data logging or Health and Safety readings are being calculated Click Restore against the relevant snapshot Be aware that this proces...

Page 27: ...fects in materials and workmanship under normal use and service for a period of ninety 90 days from the date of delivery as evidenced by a copy of the Receipt This limitation will apply where allowed...

Page 28: ...he use of the instrument is needed The rechargeable pack is normally fitted as standard to the instrument when shipped Recharging Batteries Ensure the TIGER LT is charged for at least 7 hours before u...

Page 29: ...end of the instrument step 4 below c Release the clip at the rear end of the instrument and lift the Rechargeable Battery Pack A2 away from the Instrument Body A1 coincidently sliding it slightly bac...

Page 30: ...y holder g Assemble the battery holder into the AA Battery Pack A3 refit the battery cover and fix in place using the securing screws Replace the Instrument Boot 8 ensuring that it is a snug fit aroun...

Page 31: ...tteries section of this manual ensuring that all connections are sound and the indicator lights on the charger are in order If the battery fails to charge fit another battery pack if available If usin...

Page 32: ...Demand flow regulators are recommended for the Tiger LT If flow regulators are to be used then a 0 3L min is recommended a flow adaptor should be used to avoid over pressurising the instrument sold s...

Page 33: ...et Nozzle is sealed this can bee seen in the transparent Filter Clamp when the Inlet Nozzle is removed The Inlet Nozzle can be removed for cleaning or replacement by unscrewing it from the transparent...

Page 34: ...t care Never touch the window and do not drop To remove the MiniPID 2 Sensor for cleaning or lamp replacement first ensure that the TIGER LT is turned off and that you are in a clean environment such...

Page 35: ...uminium Oxide as a very fine power CAS Number 1344 28 1 A full material safety data sheet MSDS is available on request from Ion Science Ltd The key issues are listed below Always replace the lid after...

Page 36: ...TIGER LT MANUAL Ion Science Ltd Page 36 of 41 TigerLT parts Tiger main assembly Front end filter assembly New probe assembly supplied on Tiger from January 2016...

Page 37: ...80202 Probe seal used with 880207 above Standard from January 2016 880201 Filter clamp used with 880207 above Standard from January 2016 A 880210 Probe upgrade kit Contains 880207 880202 and 880201 ab...

Page 38: ...TIGER LT MANUAL Ion Science Ltd Page 38 of 41 For more information please visit www ionscience com Tiger and select Accessories LA4TM600 10 6eV Lamp LA4SM700 11 7eV Lamp...

Page 39: ...stration Service Ion Science Ltd also offers a number of service options for your TIGER that allows you to choose the instrument cover to best suits your requirements At Ion Science Ltd we recommend t...

Page 40: ...500 8 5 hours Data log Including date time 80 000 Alarm visual Flashing Red and Amber LED Alarm audible 95 dBA 30 cm Flow Rate 220 ml min in Ambient conditions Temperature Operating 20 to 60 C 4 to 14...

Page 41: ...Part number descriptions updated page37 18 09 15 V0 5 09 V1 1 0 3 V1 2 New probe design Pages 33 36 and 37 27 01 2016 V0 5 09 V1 1 0 3 V1 3 Warranty length updated 18 02 2016 V0 5 09 V1 1 0 3 V1 4 Pa...

Reviews: