50
Ioline SmarTrac User Guide
Cleaning the Drive Shaft
Clean the drive shaft regularly to make sure the cut lines remain ac-
curate. To clean the drive shaft:
1.
Turn off the cutter and disconnect the power cord.
2.
Remove any accumulated dust and residue with a stiff bristle
brush.
Size Calibration
Over time, cutters may require calibration to account for normal wear
and tear. Typically, the accuracy of a cut is within 0.2% overall. By using
the calibration feature, the variance can be adjusted to within 0.05%.
Prepare the cutter:
1.
Open the Ioline
Control Center
program. Put the cutter in
START
mode (green LED).
2.
Load the cutter with material that is greater than 22-in wide
(60-cm model) or greater than 30-in wide (80-cm or larger mod-
els) and a minimum of 48-in long. Install a blade holder (use
cutting material) or pen (use paper material) in the carriage.
Enable
Autoloop
or manually create a service loop of material.
3.
Move the carriage and material with the
Arrow
keys so that
the blade or pen is about one inch from both the right and front
edge of the material. Set an origin.
See the
Operation
chapter for
more details on preparing to cut.
Gather the Calibration Data:
1.
Select
Calibrate, Calibrate Plotter
from the
Control Center
Menu Bar
.
2.
Select
Calibration Plot
to cut the factory stored calibration cut.
The cutter will plot a large box. (
Figure 32
.)
Figure 31.
Cleaning the drive shaft.
Warning: Do not use any
cleaning agents (beside
alcohol), water or brushes
with metal bristles to clean parts
of the plotter. Pay special atten
-
tion to keeping the drive shaft
bearings free of all liquids.
Caution
The
Scale
command does not
effect the calibration values.
Note