41
VICTOREM
2KSDI-Mini User's Manual
Command
Format
Description
Frame Number
(2KM5SDI-Mini Only)
Fnm Y
Replace the first pixel luma value with a frame counter. The
value counts from 64 to 940 before restarting to keep it
within SDI data value limits.
0 – off (default)
1 – on
PROFILE
Power-Up Profile
pup Y
0 – factory profile
1-8 – user profile
Save to Profile
sav Y
Save current settings to a user profile in flash memory
Range 1 – 8
Load Profile
lod Y
Load factory or user profile
0 – factory
1-8 – user profile
Auto save to Power-Up
Profile
asv Y
0 – off
1 – on
Auto save current settings when exiting on-screen menu
Only applies if power-up profile is set to a user profile
EXECUTE
Camera Reset
rst
Reset camera to power-up profile
LENS UNSAVED
Lens adapter reset
lnr
Reset EF lens adapter
Focus Step to Min
fsz
Step focus towards minimum
Focus Step to Infinity
fsi
Step focus towards infiinty
Move Focus to Min
fcz
Move focus to minimum setting
Move Focus to Infinity
fci
Move focus to infinity
Lens Status
lns Y
Query lens parameters/status
0 – Lens Ready
1 – Focal Length
2 – F Number
3 – Focus Near
4 – Focus Far
5 – Manual Focus
6 – Auto Focus Busy
Auto Focus
afc Y
One-shot auto focus
0 – sweep entire focus range for highest contrast position
1 – fast focus, stop at first high contrast position
COLOR UNSAVED
Auto White Balance
awb Y
One-shot white balance
0 – using full image
1 – using zone
IO Industries Inc.