3 Environmental
3.1 Temperature
The operating temperature range of the 2KSDI-Mini cameras is -30ºC to 65ºC, with 20-85% relative
humidity non-condensing. The Field Programmable Gate Array (FPGA) die and image sensor
temperatures can be monitored through the RS485 interface (see
tmp
and
stp
commands in Table 15).
The storage temperature range is -40ºC to 85ºC, 10-90% relative humidity non-condensing.
3.2 Shock and Vibration
Results of shock and vibration testing performed on 2KSDI-Mini camera are shown in Table 8.
Specification
Spec Paragraph
Method/Condition
Test Level
Details
Result
MIL-STD-810G
514.6 Vibration
3-axis Vibration Category 20
Pass
MIL-STD-810G
516.6 Shock
3-axis Shock 40G (3 /-)
Pass
MIL-STD-810G
516.6 Shock
3-axis Shock 75G (2 /-)
Pass
Table 8. Shock and vibration testing results