Model : IW-RS424-07 Hybrid EXP-

BP (COBRA) User’s Manual     

PAGE    13    OF    22   

 

Basically, The LEDs behave following the SES control signal from RAID card when working 

in SAS/SATA mode. Below is the design SPEC of the Disk indicators. 

 

SES Status 

Status Description 

Red LED 

(Error) 

Green 

LED 

(Activity

Priority 

(Hex) 

SES Control 

Power-On State (before SES client intervening)

 

Forced Condition 
Cleared 

Empty slot or disk 
unplugged 

Off 

Off 

10 

N/A (SEP internal) 

Condition Cleared 

Disk loaded or 
inserting 

Off   

ActFlash   12 

N/A (SEP internal) 

Informative

 

OK 

 

Off 

ActFlash  11 

RQST OK 

Device Off 

Power down phy or 
bay 

Off 

Off   

10 

RQST DEVICE OFF 

Reserved Device 

Hot Spare 
Do Not Remove 

Usually for RAID 

members 

 

Off 

 

ActFlash   

 

0E 

 

RQST RSVD DEVICE 

RQST HOT SPARE 

DO NOT REMOVE 

Activity

 

Consistence Check 
(Cons Chk) 

Check RAID 
consistence 

Blink_1

 

ActFlash  03 

RQST CONS CHECK 

Rebuild/Remap (disk 
array) 

Spare disk summoned 
for critical RAID 
rebuild 

Blink_1

 

ActFlash  03 

RQST REBUILD/REMAP 

Active (Activity) 

 

Off 

ActFlash  10 

RQST ACTIVITY 

Warning & Error

 

In Critical Array 

Members in degraded 
RAID 

Off

 

ActFlash  06 

RQST IN CRIT ARRAY 

In Failed Array 

Members in broken 
RAID 

On

 

ActFlash   07 

RQST IN FAILED ARRAY 

Rebuild/Remap 

Aborted 
(R/R Abort) 

Spare disk summoned 

for 
RAID rebuild yet 
aborted 

On 

ActFlash  05 

RQST R/R ABORT 

Fault 

 

On

 

ActFlash   04 

RQST FAULT 

Missing 

 

On

 

ActFlash  04 

RQST MISSING 

Predict Failing 
(Fault Sensed) 

Dying disk detected by 
enclosure 

On 

ActFlash  05 

 
COMMON CONTROL 
PRDFAIL 

Identify & Prompt

 

Identify/Locate 

 

Slow_Blink_1

  ActFlash  00 

RQST IDENT 

Ready to Insert 

 

Off 

ActFlash  0B 

RQST INSERT 

Ready to Remove 

(RMV) 

Disk spun down 

Off 

ActFlash 

 
0C 

RQST REMOVE 

Note: 

 

Blink_1                      : 

50% On and then Off in a one second circle 

 

Slow_Blink_1 :

 50% On and then Off in a 2 seconds circle 

 

ActFlash                  : 

Stay off while idle and fast flash upon I/O load 

 

Summary of Contents for Cobra IW-RS424-07

Page 1: ...W RS424 07 Hybrid EXP BP COBRA User s Manual PAGE 1 OF 22 HYBRID BACKPLANE with EXPANDER User Manual P N 2RAKVI008000 Model IW RS424 07 IW RS436 07 HYBRID EXP BP SLIMSAS MODULE BROADCOM COBRA BASED Version A0 ...

Page 2: ...in Definitions 7 Connector Locations and LED Indicators 9 Connector Locations 9 LED Indicators 9 Hardware Specification 10 LED Behavior 11 Disk Bay LED 11 System Alarm 14 Smart Fan Control 15 Firmware Upgrade 17 Expander Chipset SAS3x36R Firmware Upgrade Description 17 Out Of Band through serial console 17 M058 Micro controller Firmware Upgrade Description 19 Management 21 Useful Console Commands ...

Page 3: ...Pin 5V and 1 piece of 2 4 Pin 12V power receptacles support up to 5V 48A 12V 32A current to satisfy the power needs of fully loaded HDDs 24 HDDs depends on backplane model The backplane implemented with smart fan control feature to support wide variety of fan modules by auto calibrating the installed fan modules at system boot This feature provides an efficient way to control the thermal heat exha...

Page 4: ...Model IW RS424 07 Hybrid EXP BP COBRA User s Manual PAGE 4 OF 22 Physical Outlook BOTTOM VIEW TOP VIEW ...

Page 5: ...Model IW RS424 07 Hybrid EXP BP COBRA User s Manual PAGE 5 OF 22 Mechanical ...

Page 6: ...cription 1 Host facing interface NVME1 NVME4 7 System_Fail LED JB1 2 Host facing interface SAS3 CN1 CN2 CN3 8 Mute_Button JB2 3 Firmware Programming Header JD1 9 Firmware Programming Header JC3 4 Main Power Connector PW1 2 PW3 4 10 I2C Header JC1 JC2 5 FAN Connector FAN1 FAN4 11 Buzzer SUB1 6 M B Fan Speed Control JM1 12 SAS3x36R Expander chip U1 ...

Page 7: ... 12V 5 8 Ground PW3 PW4 Power 2 3 Pin Connector PIN Definition 1 3 5V 4 6 Ground FAN1 FAN4 FAN 4 Pin Connector PIN Definition 1 Ground 2 12V 3 Tachometer 4 PWM Output JB1 SYS_ERR_LED Header PIN Definition 1 SYS_ERR_LED _ 2 SYS_ERR_LED _ JB2 MUTE_BUTTON Header PIN Definition 1 MUTE_BUTTON_ 2 MUTE_BUTTON_ JC1 JC2 I2C Header JM1 JM2 Function Description PIN Definition ...

Page 8: ...finition PIN Definition 1 SDB_TX 2 1 8V 3 SDB_RX 4 Ground 5 UART_TX 6 NC 7 UART_RX 8 Ground 9 Ground 10 3 3V JD1 JD2 Firmware Programming Connector PIN Definition PIN No Definition 2 ICE_CLK 1 VCC 4 ICE_DATA 3 Key 6 ICE_RST 5 Ground JM1 M B FSC 3 Pin Connector PIN Definition 1 MB_PWM 2 BP_TACH 3 Ground DISK1 5 9 13 DISK4 8 12 16 DISK2 3 6 7 DISK10 11 14 15 DISK17 DISK24 ...

Page 9: ...5 SATA SAS Disk 17 24 LED Indicators No Location Description Location Description A DG1 DG4 DISK1 DISK4 Power LED LED1 4 DISK1 DISK4 Activity Failure LED B DG5 DG8 DISK5 DISK8 Power LED LED5 8 DISK5 DISK8 Activity Failure LED C DG9 DG12 DISK9 DISK12 Power LED LED9 12 DISK9 DISK12 Activity Failure LED D DG13 DG16 DISK13 DISK16 Power LED LED13 16 DISK13 DISK16 Activity Failure LED E DG17 DG20 DISK17...

Page 10: ...Monitor HDD bay inside temperature Buzzer SUB1 for Over temperature and FAN fail alerting High Speed Connector SFF 8654 SLIMSAS 38PIN Connector 8 NVME1 NVME8 SFF 8680 SAS29Pin Connector 16 for SATA SAS3 Disk SFF 8639 U 2 68Pin Connector 8 DISK1 5 9 13 DISK4 8 12 16 for SATA SAS3 Disk or NVMe SSD Power Signal Connector P4 2mm Disk Drive Power Connector 3 PW1 PW2 12V PW3 PW4 5V SYS_ERR_LED JB1 Turn ...

Page 11: ...e are 2 parts of LED Management on the backplane One is for SAS and another is for NVMe Please note that the disk slots can only accommodate SAS SATA or NVMe disk at a time since they share the same disk connector For SAS application The LEDs behave by following SGPIO signal coming through sideband bus inside the SFF 8643 cables Please refer to Section 2 for SGPIO settings When SGPIO Jumper settin...

Page 12: ...2C bus The Green LEDs for Activity behave according to the signal from P11 Activity of the disk connectors Examples of NVMe connections to Broadcom RAID HBA controller Each pair of VPP over I2C signal supports 2 pieces of NVMe disks LED management The I2C bus is leaded to odd number NVMe connector SlimSAS or SlimSAS to manage its corresponding and the following NVMe disks For example NVMe1 and NVM...

Page 13: ...istence Blink_1 ActFlash 03 RQST CONS CHECK Rebuild Remap disk array Spare disk summoned for critical RAID rebuild Blink_1 ActFlash 03 RQST REBUILD REMAP Active Activity Off ActFlash 10 RQST ACTIVITY Warning Error In Critical Array Members in degraded RAID Off ActFlash 06 RQST IN CRIT ARRAY In Failed Array Members in broken RAID On ActFlash 07 RQST IN FAILED ARRAY Rebuild Remap Aborted R R Abort S...

Page 14: ...ail When the Fan RPM is lower than 50 of the expected speed the indicator goes ON And it would go off when the issue is resolved or not existed Overheat When the system temperature at the backplane area is going beyond 45 C the System Fail LED is turned ON And would be turned off when temperature is going under 44 C Note When the system alarm is triggered the Buzzer beeps along with it and stops b...

Page 15: ... next reboot 2 Backplane starts fan calibration and calculates the corresponding PWM duty cycle for each level There are totally 8 speed levels to be sensed and used until next system boot 3 The 8 levels of fan speed are mapped to the temperature readings detected by thermistor spreading from 25 to 45 C in 3 75 degree C step 4 In normal operation when the system temperature changes to next level t...

Page 16: ...Model IW RS424 07 Hybrid EXP BP COBRA User s Manual PAGE 16 OF 22 ...

Page 17: ...the same time Ether one can be upgraded independently when required How to upgrade firmware 1 Out Of Band through serial console 2 In Band through SCSI Command Out Of Band through serial console InWin s SAS 3 12Gps Backplane implements a serial UART port allowing users to conduct firmware upgrade through it 1 Require a proprietary serial cable InWin made Please note that the connector to Backplane...

Page 18: ... RS424 07 Hybrid EXP BP COBRA User s Manual PAGE 18 OF 22 4 Configure serial port setting as 115200 N 8 1 5 Command fdl 0 0 y for system firmware upgrade in serial console Sending system firmware through Xmodem ...

Page 19: ... to make new firmware take effect M058 Micro controller Firmware Upgrade Description The passive backplanes are planted Nuvoton M058 series MCUs for hosting disk LED indication Fan speed control and system fail alarm These MCUs are preprogrammed in manufacturing In most cases the MCUs are not required to reprogram unless there is issue needed to fix How to upgrade firmware 1 Require Nuvoton ARM Co...

Page 20: ...OF 22 Nuvoton ICP Programming tool software 2 Connect Nu Link USB end to a host and the SWD end to Backplane ICE connector for each MCU 3 Make sure device is connected and select the binary file being programmed and then click on Start button to program firmware ...

Page 21: ...gement To manage backplane users can connect a serial console cable to backplane or expander UART through RS232 COM port on system host Refer to Out Of Band through serial console Page14 for the details of the serial console cable and the console terminal setting There are some useful commands for users to check expander status conduct firmware update and debug issue when required ...

Page 22: ...able up PhyNum D no arguments displays default output help displays detailed help information edfb subcommand displays EDFB info power subcommand displays power mgmt info up filters to display connected phys only cable subcommand displays cable mgmt info PhyNum is a valid phy index and filters the output to display info about that phy Display or reset all phy counters counters config event reset n...

Reviews: