iMars grid-tied solar inverters Display panel
48
Setting item
LCD display
Instruction
Set power
set power
P-Lmt
Mode
LmtPower
P.Factor
Limit Mode Invalid
Invalid
Auto
Manual
Limit Power
100%
Power Factor
Grid Tied Mode
Normal Mode
Power Factor 1.00
Input password
0000
The password is needed when enter into
the interface of “Set power”. Get
the
password from the supplier if necessary.
There are 3 submenus:
ķ
P-Lmt Mode:
invalid (limited power function is
invalid),auto (special for single
phase) ,manual (set the limit of output
value manually);
ĸ
LmtPower: this
function is only valid when the P-Lmt
Mode is manual, the percentage is that
of the rated power and the setting range
is from 10% to 100%;
Ĺ
p.Factor:
includes normal model (default value
“1”), current advanced mode and current
hysteresis mode and the setting rage is
-0.9-0.99.
(the machine of three phase only has the
function of
Ĺ
)