iMars grid-tied solar inverters Operation
38
(5) Dismantle the fan mounting plate as shown in Figure 5.2.
(6) Remove the damaged fans, and replace good fans, connect the power lines and control
signal lines, as shown in Figure 5.3.
Figure 5.3 Replace fans
(7) Assembly the cooling chamber or fan mounting plate into inverter.
(8) Re-install the inverter to its original position as Section 4 of the content.
(9) Repeat Section 5.1 operating content.
(10) Restart the inverter.
Note
z
Once the inverter alarms and stops, do not be restarted before all the fault has
been ruled out. Checks should be strictly in accordance with Section 5.1 steps.