Goodrive350A series high-performance multifunction VFD
Basic operation guidelines
-43-
Up to 16 monitoring parameters can be added to the list of parameters displayed in stopped state;
and up to 32 monitoring parameters can be added to the list of parameters displayed in running state.
5.4.4 Adding parameters to the user defined parameter list
You can choose
Menu
>
Parameter groups
, choose a submenu, and enter a specific function group
and then a specific function code to add the parameter to the user defined parameter list.
GD350A
16:02:35
Forward
Local
Ready
P01.00
:
StartRun Mode
P01.01
:
DirectStart Freq
P01.02
:
StartFreq HoldTime
P01.03
:
Prestart BrakeCur
P01.04
:
Prestart BrakeTime
P01.05
:
Acc/Dec Mode
GD350A
16:02:35
Sure to add to user defined
parameters?
Forward
Local
Ready
Back Add Sele
Back Home OK
Figure 5.14 Adding parameter diagram 2
Press
key to enter addition interface, and press
key,
key or
key to confirm
the addition operation. If this parameter is not included in the original user defined parameter list, the
newly-added parameter will be at the end of the list; if this parameter is already in the user defined
parameter list, the addition operation will be invalid. If
key or
key is pressed without
selecting addition operation, it will return to parameter setup list menu.
All the function code groups under the submenu can be added to user defined parameter list. Up to
64 function codes can be added to the user defined parameter list.
5.4.5 Editing user defined parameters
After accessing a specific function code under the
User defined parameters
menu, you can press
the
key,
key or
key to enterthe parameter edit interface. After entering the edit
interface, the present value is highlighted. Press the
key and
key to edit the parameter
value, and the corresponding parameter item of current value will be highlighted automatically. After
the edit operation is completed, press
or
key to save the selected parameter and return
to the previous menu; or press
key to maintain the value and return to the previous menu.
Present: 0
Auth:
√
0
:
SVC0
1
:
SVC1
2
:
SVPWM
Present: 1
Auth:
√
1
:
SVC 1
2
:
SVPWM
3
:
VC
Default: 2
Default: 2
GD350A
16:02:35
P00.00: Speed Ctrl Run Cmd
P00.02: Comm Cmd Channel
P00.03: Max Output Freq
P00.04: RunFreq Up Limit
P00.05: RunFreq Low Limit
Fwd
Local
Ready
P00.01: Run Cmd Channel
3
:
VC
Note: If 0/1/3 is selected, it is required to set motor
nameplate parameters first and perform motor
parameter autotuning.
Note: If 0/1/3 is selected, it is required to set motor
nameplate parameters first and perform motor
parameter autotuning.
Back Edit Sele
Back Home OK
Back Home OK
Figure 5.15 Editing user defined parameters
In the interface, the "Auth" field on the top right indicates whether this parameter is editable or not.
"
√
" indicates the set value of this parameter can be modified under the present state.