Goodrive300-LIFT series inverter
Function parameters
-61-
Function
code
Name
Detailed instruction of parameters
Default
value
Modify
P09.24
DEC time for
creeping to stop
0.1
–
360.0s
During deceleration to stop, when the speed
reached the value set in
, the curve of
deceleration to stop switches to those set in
2.0s
○
P09.25
Speed threshold
for light-load
detection in
open-loop
control
5.00
–
20.00 Hz
5.00 Hz
○
P10 Group Non-weighing compensation
P10.00
Enable
non-weighing
compensation
0: Disable
1: Enable
0
◎
P10.01
Load
compensation
time
0.000
–
5.000s
0.400
◎
P10.02
Load
compensation
decrease time
0.000
–
5.000s
0.100
◎
P10.03
Load
compensation
ASR gain
0
–
100.0
25.0
○
P10.04
Load
compensation
ASR integral
time
0.01
–
10.000s
0.160
○
P10.05
Load
compensation
current
coefficient KP
0
–
1000
1000
○
P10.06
Load
compensation
current
coefficient KI
0
–
1000
0
○
P10.07
APR gain
0
–
100.0
0.0
○
P10.08
APR integral
time
0.001
–
10.000s
0.001
○