INVISIBLE FENCE ICT 801 Installation Manual Download Page 2

Foreword 

This document contains important information regarding the installation and operation of 
the ICT 801, ICT 802, and ICT 810 Transmitters, and the R21 v4.0 Titanium Computer 
Collar

®

. Prior installation of signal field wire is assumed. Review all instructions before 

installation and use. 

 

System Information 

The ICT 801, ICT 802, and ICT 810 
Transmitters are used as part of an Invisible 
Fence

®

 Brand pet containment system. These 

transmitters must always be installed in a dry, 
protected area to insure they will not be 
exposed to the elements. 
 
  
The transmitters are connected to an external signal field wire and send a coded, digital 
signal along the entire length of wire. The following wire specification should be 
followed:  
 

 

ICT 801 / ICT 802  
Up to 3,000 ft.

 

ICT 810 
Up to 5,000 ft.

 

Feet of twisted pair

 

150 feet

 

200 feet

 

Wire size 

14 AWG

 

12 AWG *

 

Jacket 

PE .045”

 

PE .045”

 

 

*

12 AWG is recommended, however, it may require a pigtail to 14 AWG for insertion  

into the LP-4100 or LP-4200 connectors.

 

 

The ICT 801 and ICT 802 are programmable to transmit a digital signal either at 7KHz 
or at 10KHz, whereas the ICT 810 transmits only a 7KHz digital signal.  

The ICT 801, 

ICT 802, and ICT 810 Transmitters are only compatible with the R21 v4.0 Titanium 
Computer Collar

®

.

 All ICT 801, ICT 802, and ICT 810 Transmitters have removable 

circuit boards that can be replaced if damaged.  
 

Planning the Installation 

Install the transmitter in a dry indoor location, near a grounded 110VAC electric outlet 
that offers easy access to the outdoors. A garage or basement is usually the best 
location. 

If you are not sure the intended outlet is grounded, use a 3-wire circuit 

analyzer or contact an electrician.

 To fasten the transmitter base to the wall, you 

need four ¾ inch long (19mm), #8, or #10 pan-head sheet metal screws. 

 

Caution: Never install a system or equipment, or service any equipment, during a 

thunderstorm or electrical storm, or when thunder or lightning is in your area. 

Summary of Contents for ICT 801

Page 1: ...Installation Manual ICT 801 ICT 802 ICT 810 Transmitters R21 v4 0 Computer Collar Receiver www invisiblefence com...

Page 2: ...AWG is recommended however it may require a pigtail to 14 AWG for insertion into the LP 4100 or LP 4200 connectors The ICT 801 and ICT 802 are programmable to transmit a digital signal either at 7KHz...

Page 3: ...wires into a black connector hole marked TRANSMITTER of the LP 4100 or LP 4200 in the same manner as the signal field wires connected in step 1 Repeat for the remaining twisted pair wire Remember inse...

Page 4: ...t conditions may cause the GFCI to trip You must instruct the homeowner to reset the tripped CFCI outlet in order for the Invisible Fence Brand system to function properly IMPORTANT NOTE Always use a...

Page 5: ...ICT 801 No indicator light on the circuit board L1 Freq Select either 7K or 10K signal for Loop 1 The default setting is 7K L1 Signal Select either Indoor or Outdoor mode for Loop 1 The default settin...

Page 6: ...LED circuitry ON or OFF If OFF is selected all LEDs for Loop 2 will not light L2 Freq Select either 7K or 10K signal for Loop 2 if the loop is ON L2 Signal Select either Indoor or Outdoor mode for Loo...

Page 7: ...Freq ICT 810 is always set to 7K Range ICT 810 range can be set to LOW or HIGH This setting adjusts the sensitivity of the signal field adjustment knob Using the LOW range setting allows for smaller...

Page 8: ...r ro og gr ra am mm mi in ng g t th he e I IC CT T 8 80 01 1 I IC CT T 8 80 02 2 a an nd d I IC CT T 8 81 10 0 T Tr ra an ns sm mi it tt te er rs s ICT 801 loop can be up to 3000 feet long ICT 810 loo...

Page 9: ...between each setting option 4 Press and release the S1 button to move to the next setting 5 Continue until all choices are selected 6 The cursor LED will stop blinking approximately ten seconds after...

Page 10: ...If a backup battery is not installed the Batt Fault system indicator LED on the transmitter circuit board will be ON IMPORTANT The recommended battery has a limited shelf life and should be replaced e...

Page 11: ...ge the correction level of the Invisible Fence Brand R21 v4 0 Titanium Computer Collar receiver it only changes the width of the signal field You can check the width of the signal field by holding the...

Page 12: ...o set the Break Alert to activate at more than a 25 reduction in set signal field width 1 Set the initial signal field width to the desired operational signal field width Note the position of the indi...

Page 13: ...djust the collar so it is snug enough to slide one finger between the correction post and the pet s neck 4 The fit of the Invisible Fence Brand Computer Collar receiver should be adjusted as necessary...

Page 14: ...ttery RED Replace NOW Do not rely on the Invisible Fence Brand system to contain the pet The owner must become familiar with the Power Cap battery status indicators For detailed instructions on how to...

Page 15: ...mall thin coin in the slot on top of the Power Cap battery to turn it clockwise until the slot on the top of the Power Cap battery is lined up with the two small raised tabs on the bottom of the recei...

Page 16: ...accept any interference received including interference that may cause undesirable operation Changes or modifications not expressly approved by the party responsible for compliance could void the user...

Reviews: