12
Setting the Break-Alert
®
Detection Level:
The Break Alert
®
alarm can be set to make a sound when the signal field width is
reduced by 25% or more of the set signal field width.
Read entire procedure before performing.
Only the loops turned on will be
programmed.
Option #1:
To set the Break Alert
®
to activate when a 25% reduction in set signal field
width occurs:
1. Set the signal field width for desired system operation.
2. If battery backup is being used, remove 12VDC battery power wire harness from transmitter
connector J2 (see picture below).
3. Remove 12VAC power from transmitter connector J1.
4. Press and hold S2 button while reconnecting 12VAC power back to transmitter connector
J1.
5. Continue holding S2 button for approximately five more seconds.
6. Release S2 button.
7. Break Alert
®
levels are now set. Setting will remain in memory even after power is removed.
8. Reconnect battery backup wire harness to transmitter connector J2, if applicable.
Option #2:
To set the Break Alert
®
to activate at more than a 25% reduction in set
signal field width:
1. Set the initial signal field width to the desired operational signal field width. Note the position
of the indicator on the adjustment device.
2. Now adjust the signal field width to
less than
the desired operational signal field width.
3. Complete steps 2 – 6 under Option #1.
4. Adjust the signal field width to the
desired
operational field width.
5. Break Alert
®
levels are now set. Setting will remain in memory even after power is removed.
Option #3:
To set the Break Alert
®
level back to the default settings (less than 1 foot).
1. Set the signal field width to the lowest setting (turn signal field adjustment all the way
counterclockwise).
2. Complete steps 2 – 6 under Option #1.
3. Set the signal field width to the desired operational field width.
4.
Break Alert
®
levels are now set. Setting will remain in memory even after power is removed.
IMPORTANT: During a wire break,
the alarm sounds and the
Saturation LED L1 and/or L2 will light to
notify which loop the break is on. The
alarm will also sound if the signal field
adjustment setting is below the
programmed Break Alert
®
level.