Energy Distribution 2015 REVISION JULY 2020
20
R
EMOVAL
A
ND
D
ISPOSAL
O
F
A
SHES
You can leave a thin layer of ashes in the firebox if
preferred. Allow fire to die down or go out completely.
It is important to prevent ashes from building up
around the front door opening or they will spill out, or
they can pack into the gasket channel and prevent
proper sealing. To remove ashes, use a fireplace
shovel. Avoid removing large live coals by pushing
them to the side and removing only the finer ash with
a shovel.
Disposal of ashes - Ashes should be placed directly
into a
metal
container with a tight fitting lid. Do not
place any other items or trash into the metal
container. Do not pour water into the container.
Replace the container’s lid and allow the ashes to
cool. Never place the ash disposal container on a
combustible surface or vinyl flooring, as the container
could be
hot!
Pending disposal, place the closed ash container on
a non-combustible floor or on the ground outside, well
away from all combustible materials, liquid fuels, or
vehicles. Retain ashes in the closed container until all
coals thoroughly cool.
If the ashes are disposed of by burial in soil or
otherwise locally dispersed, they should be retained
in the closed container until all cinders have
thoroughly cooled.
NEVER
place ashes in wooden or plastic containers,
in trashcans with other trash, or in paper or plastic
bags, no matter how long the fire has been out.
Coals within a bed of ashes can remain hot for
several days once removed from the firebox.
M
AINTENANCE
I
NSPECTION AND
R
EPLACEMENT
P
ROCEDURES
WARNING : THIS WOOD HEATER NEEDS
PERIODIC INSPECTION AND REPLACEMENT FOR
PROPER OPERATION. IT IS AGAINST FEDERAL
REGULATIONS TO OPERATE THIS WOOD
HEATER IN A MANNER INCONSISTENT WITH
OPERATING INSTRUCTIONS IN THIS MANUAL
I
NSPECTING AND REMOVING
/
REPLACING THE
BAFFLE
1.
Allow the stove and ashes to fully cool.
2.
Lift up on the right side baffle, and gently pull the
left side baffle down and out of the stove.
Summary of Contents for AARON
Page 14: ...Energy Distribution 2015 REVISION JULY 2020 14 Figure 8 Chimney Height Requirements...
Page 15: ...Energy Distribution 2015 REVISION JULY 2020 15 Figure 9 Typical Chimney Configurations...
Page 25: ...Energy Distribution 2015 REVISION JULY 2020 25 SAFETY LABEL...
Page 26: ...Energy Distribution 2015 REVISION JULY 2020 26...
Page 27: ...Energy Distribution 2015 REVISION JULY 2020 27 WARRANTY...
Page 28: ...Energy Distribution 2015 REVISION JULY 2020 28...
Page 29: ...Energy Distribution 2015 REVISION JULY 2020 29 ANNEX PARTS...
Page 31: ...Energy Distribution 2015 REVISION JULY 2020 31...