Optidrive P2 Advanced User Guide Revision 2.00
www.invertekdrives.com
73
G
en
er
al Tec
hni
cal
a
n
d P
er
fo
rman
ce Da
ta
8
8.2.3.
525 Volt Input
Frame
Size
Supply
Voltage
Power
Rating
(kW)
Input
Current
(A)
iTHD
(%)
AC
Line
Choke
Input
Current
(A)
iTHD
(%)
Output
Current
(A)
7
525V, 3ph
132
191.9
57.5
N/A
N/A
N/A
185
160
214.9
50.5
N/A
N/A
N/A
205
185
261.7
44.8
N/A
N/A
N/A
255
200
275.3
43.2
N/A
N/A
N/A
275
The data above is provided to show typical values. Results measured at the point of installation may vary according to the installation site and
load conditions Test results are measured under the following conditions :-
525 Volt RMS AC Supply Voltage
Operating IE2 motor with matching power rating according to the drive
Operated at full rated output current capacity
8.2.4.
575 Volt Input
Frame
Size
Supply
Voltage
Power
Rating
(kW)
Input
Current
(A)
iTHD
(%)
AC
Line
Choke
Input
Current
(A)
iTHD
(%)
Output
Current
(A)
2
575V, 3ph
0.75
3.4
N/A
N/A
N/A
N/A
2.1
1.5
4.2
N/A
N/A
N/A
N/A
3.1
2.2
4.9
N/A
N/A
N/A
N/A
4.1
4.0
8.6
N/A
N/A
N/A
N/A
6.5
5.5
12.2
N/A
N/A
N/A
N/A
9
3
575V, 3ph
7.5
15.1
N/A
N/A
N/A
N/A
12
11
20.9
N/A
N/A
N/A
N/A
17
15
25.5
N/A
N/A
N/A
N/A
22
4
575V, 3ph
15
26.0
N/A
N/A
N/A
N/A
22
18.5
32.2
N/A
N/A
N/A
N/A
28
22
39.1
N/A
N/A
N/A
N/A
34
30
48.9
N/A
N/A
N/A
N/A
43
5
575V, 3ph
37
59.5
N/A
N/A
N/A
N/A
54
45
70.4
N/A
N/A
N/A
N/A
65
6
575V, 3ph
55
90.6
N/A
N/A
N/A
N/A
78
75
121.1
N/A
N/A
N/A
N/A
105
90
143.2
N/A
N/A
N/A
N/A
130
110
158.4
N/A
N/A
N/A
N/A
150
The data above is provided to show typical values. Results measured at the point of installation may vary according to the installation site and
load conditions Test results are measured under the following conditions :-
575 Volt RMS AC Supply
Operating IE2 motor with matching power rating according to the drive
Operated at full rated output current capacity