Troubleshooting

Fault Code Messages

Fault Code

No.

Description



01

Brake channel over current

r

02

Brake resistor overload



03

Output Over Current

r

04

Motor Thermal Overload (I2t)



06

Over voltage on DC bus

U

07

Under voltage on DC bus



08

Heatsink over temperature

U

09

Under temperature

r

11

External trip



12

Optibus comms loss



13

DC bus ripple too high



14

Input phase loss trip

 

15

Output Over Current



16

Faulty thermistor on heatsink



17

Internal memory fault (IO)

4 

18

4-20mA Signal Lost



19

Internal memory fault (DSP)



21

Motor PTC thermistor trip 



22

Cooling Fan Fault (IP66 only)



23

Drive internal temperature too high

U

26

Output Fault



41

Autotune Fault



50

Modbus comms loss fault



51

CAN comms loss trip

NOTE

 Following an over current or overload trip (1, 3, 4, 15), the drive may not be reset until the reset time delay has elapsed 

to prevent damage to the drive.

Ñ82-E3I66-IN_V1.05JÓ

82-E3I66-IN_V1.05

Invertek Drives Ltd.  

Offa's Dyke Business Park, Welshpool, Powys SY21 8JF United Kingdom 

Tel: +44 (0)1938 556868   Fax: +44 (0)1938 556869 

www.invertekdrives.com

Summary of Contents for OPTIDRIVE E3 Series

Page 1: ...Quick Start Guide AC Variable Speed Drive IP66 NEMA 4X 0 37kW 22kW 0 5HP 30HP 1 10V 230V Single Phase input 230V 480V 3 Phase input Switched Non switched...

Page 2: ...rrent x 10 2 PREPARE Prepare the Mounting Location The Optidrive must be mounted in a vertical position only Installation should be on a suitable flat flame resistant surface Do not mount flammable ma...

Page 3: ...0 0 1 1 8 33 4 1 31 275 0 10 82 240 0 9 44 4 9 5 20 9 Mounting Clearance Drive Size X Above Below Y Either Side mm in mm in All Frame Sizes 200 7 87 10 0 39 NOTE Typical drive heat losses are approxim...

Page 4: ...regulations Maximum dimensions are given in the Rating Tables section of this Quick Start Guide Install the Wiring L1 L L3 EMC Gland plate can be removed for installation L2 N U V W 1 2 3 4 5 6 7 8 9...

Page 5: ...e side of this equipment and shall be rated 480Volt phase to ground 480 Volt phase to phase suitable for over voltage category iii and shall provide protection for a rated impulse withstand voltage pe...

Page 6: ...ommon 10 RL1 Output Relay Function defined by P 18 See Parameter List 1 1 RL2 Output Relay Connection Example Factory Default Functions No Description DI1 0 1 Open Stop Closed Run DI2 Open Forward Rot...

Page 7: ...ress the Navigate key for 1 second The display will show the motor power kW If P 10 0 pressing the Navigate key for 1 second will display the motor speed RPM Changing Parameters Press and hold the Nav...

Page 8: ...7 Motor Rated Voltage Back EMF at rated speed PM BLDC 0 250 500 230 400 V P 08 Motor Rated Current Drive Rating Dependent A P 09 Motor Rated Frequency 10 500 50 60 Hz P 10 Motor Rated Speed 0 30000 0...

Page 9: ...00 s P 25 Analog Output Function Select 0 11 8 Digital Output Mode Logic 1 24V DC Analog Output Mode 0 Drive Enabled Running 1 Drive Healthy 2 At Target Frequency Speed 3 Drive Tripped 4 Output Freque...

Page 10: ...0 10 Unidirectional External 0 10Volt reference pot A 0 20 External 0 20mA signal t 4 20 External 4 20mA signal trip on loss r 4 20 External 4 20mA signal t 20 4 External 20 4mA signal trip on loss r...

Page 11: ...9 2 25 25 8 8 10 5 50 3 4 5 29 2 40 40 8 8 15 3 25 200 240 10 V 3 Phase Input 3 Phase Output 1 0 37 0 5 3 4 6 6 8 8 2 3 1 0 75 1 5 6 10 10 8 8 4 3 1 1 5 2 8 9 16 15 8 8 7 2 1 5 2 8 9 16 15 8 8 7 100 2...

Page 12: ...heatsink 17 Internal memory fault IO 18 4 20mA Signal Lost 19 Internal memory fault DSP 21 Motor PTC thermistor trip 22 Cooling Fan Fault IP66 only 23 Drive internal temperature too high 26 Output Fau...

Reviews: