Only new TAG – 

reads tag only one time even when it is still close to the reader. Next

reading occurs only when the transponder is removed and again applied.

User Defined (x 0.1 s)

 - setting the desired reading delay.

5.1

Configuration Examples

Keyboard emulation, sending "code card" prefix, card number and enter:

After applying the card in the active window will be displayed string: 

kod karty:123456789012 

 and inserted „enter” symbol

INVEO s.c.  43-340 Kozy ul. Rzemieślnicza 21 tel: +48 781 133 283 www.inveo.com.pl 

version 0.40 01.02.2018

Summary of Contents for RFID-USB-DESK Reader

Page 1: ...User manual RFID USB DESK Reader INVEO s c 43 340 Kozy ul Rzemieślnicza 21 tel 48 781 133 283 www inveo com pl version 0 40 01 02 2018 ...

Page 2: ...principles of safety and maintenance Please also keep the user manual so that you can read it during later use Remember The manufacturer is not liable for any damage caused by improper use of the device for its intended purpose or improper handling as well as fault driver resulting from improper use INVEO s c 43 340 Kozy ul Rzemieślnicza 21 tel 48 781 133 283 www inveo com pl version 0 40 01 02 20...

Page 3: ... INSTALLATION AND USE OF THE MODULE 5 3 4 UTILISATION OF THE MODULE 5 4 CONSTRUCTION OF THE DEVICE 6 4 1 GENERAL FEATURES 6 5 CONFIGURATION 7 5 1 CONFIGURATION EXAMPLES 9 NOTES 11 Before starting work with the controller read The User manual and follow the instructions contained therein INVEO s c 43 340 Kozy ul Rzemieślnicza 21 tel 48 781 133 283 www inveo com pl version 0 40 01 02 2018 ...

Page 4: ...ee if the following conditions are met all repairs alterations extensions and device calibrations are performed by the manufacturer or authorized service supply network installation meets applicable standards in this regard the device is operated in accordance with the recommendations outlined in this manual the device is used as intended ProThe manufacturer assumes no responsibility for consequen...

Page 5: ...atmospheric pressure 700 1060hPa Recommended conditions for transportation temperature 10 C 45 C humidity 20 95 atmospheric pressure 700 1060hPa 3 3 Installation and use of the module The module should be used following the guidelines shown in next part of the user manual 3 4 Utilisation of the module When it becomes necessary to liquidate the device e g after the time of use please contact the ma...

Page 6: ...f ON Read switching on for 0 5 second after the correct reading of the card code Technical data Supply voltage USB 5VDC the device is powered from the USB port of a computer Transponders Standard supported transponders UNIQUE Frequency 125kHz Coding Manchester Reading distance approximately 10cm Communication USB port keyboard emulation or a virtual COM port Dimensions INVEO s c 43 340 Kozy ul Rze...

Page 7: ...s detected in the system USB Status Connected user can proceed to its configuration Operating mode USB mode USB Keyboard Emulator the reader in the system will appear as a standard USB keyboard Approaching the card enters tag code in apropriet format in active window INVEO s c 43 340 Kozy ul Rzemieślnicza 21 tel 48 781 133 283 www inveo com pl version 0 40 01 02 2018 ...

Page 8: ... which it will display the card code Binary send 5 bytes of code card HEX LowerCase Letter card code in hexadecimal format with lowercase letters HEX UpperCase Letter card code in hexadecimal format with large letters HEX UpperCase Letter Minus card code in hexadecimal format with large letters and cons separating bytes of code Some applications require data input in decimal format In this case se...

Page 9: ...efined x 0 1 s setting the desired reading delay 5 1 Configuration Examples Keyboard emulation sending code card prefix card number and enter After applying the card in the active window will be displayed string kod karty 123456789012 and inserted enter symbol INVEO s c 43 340 Kozy ul Rzemieślnicza 21 tel 48 781 133 283 www inveo com pl version 0 40 01 02 2018 ...

Page 10: ... User can control the beeper and LEDs Sending a byte to the virtual serial port causes the appropriate response Meaning of the bits of send byte BIT 7 6 5 4 3 2 1 0 Meaning LED3 LED2 LED1 INVEO s c 43 340 Kozy ul Rzemieślnicza 21 tel 48 781 133 283 www inveo com pl version 0 40 01 02 2018 ...

Page 11: ...Notes INVEO s c 43 340 Kozy ul Rzemieślnicza 21 tel 48 781 133 283 www inveo com pl version 0 40 01 02 2018 ...

Reviews: