6
Connecting the Battery
1. Remove power to the vehicle/device prior to installation of the U1LiFePRO™ battery.
2. Remove all other batteries from the system prior to replacing them with U1LiFePRO™
batteries.
3. Remove the protective battery terminal covers from the terminals. Retain these covers in
the event that you need to remove or move the battery at some future time.
4. Attach the negative cable from the device to the negative terminal on the battery.
5. Attach the positive cable from the device to the positive terminal on the battery.
6. Attach the signal communications cable to the RJ45 ports if needed.
7. If the battery charger is integrated with the device drawing power from the U1LiFePRO™
battery, then please follow manufacturers recommended sequence for each battery connection.
Please contact Inventus Technical Support if the system requires more than 10 batteries.
Parallel connections
The PROformance batteries can be connected in parallel to increase your energy requirements.
You may connect up to 10 batteries for the M-12V40-U1 and M-24V20-U1 models. These batteries
cannot be connected in series. Refer to wiring diagram below.
Single Install
Parallel Connection
Pack (
-
)
Signal Cable
(System)
Pack (
+
)
Signal Cable
(System)
Pack (
+
)
Pack (
-
)
Signal Cable
(Pack to Pack)