   Contact an authorised service technician for repair or maintenance of this unit.
   

The appliance shall be installed in accordance with national wiring regulations.

   This appliance is not intended for use by persons(including children) with reduced 
   physical, sensory or mental capabilities, or lack of experience and knowledge, unless 
   they have been given supervision or instruction concerning use of the appliance by a 
   person responsible for their safety. 
   Young children should be supervised to ensure that they do not play with the air conditioner.
   

Do not operate your air conditioner in a wet room such as a bathroom or laundry room.

   Installation work must be performed in accordance with the national wiring standards by 
   authorised personnel only. 

CAUTION

WARNING

      Read the follow SAFETY PRECAUTIONS carefully before installation.
      Incorrect installation due to ignoring of the instruction will cause harm or damage, and the
      seriousness is classified by the following indications.

This symbol indicates the possibility of death or serious injury.

The items to be followed are classified by the symbols:

Symbol will background white denotes item that is PROHIBITED from doing.

CAUTION

This symbol indicates the possibility of injury or damage to property.

WARNING

1)  Engage dealer or specialist for installation. If installation done by the user is defective, it will 
     cause water leakage, electrical shock or fire.

2)  Install according to this installation instructions strictly. If installation is defective, it will cause
     water leakage, electrical shock or  fire.

3) Use the attached accessories parts and specified parts for installation. otherwise, it will cause
    the set to fall, water  leakage, electrical shock or  fire.

4)  Install at a strong and firm location which is able to withstand the set s weight. If the strength is
     not enough or installation is not properly done, the set will drop and cause injury.

5)  For electrical work, follow the local national wiring standard, regulation and this installation 
     instructions. An independent circuit and single outlet must be used. If electrical circuit capacity
     is not enough or defect found in electrical work, it will cause electrical shock or fire.

6)  Use the specified cable and connect tightly and clamp the cable so that no external force will 
     be acted on the terminal. If connection or fixing is not perfect, it will cause heat-up or fire at the 
     connection.

7)  Wiring routing must be properly arranged so that control board cover is fixed properly. If 
     control board cover is not fixed perfectly, it will cause heat-up at connection point of terminal, 
     fire or electrical shock.

8)  When carrying out piping connection, take care not to let air substances other than the specified 
     refrigerant go into refrigeration cycle. Otherwise, it will cause lower capacity, abnormal high 
     pressure in the refrigeration cycle, explosion and injury.

9)  Do not modify the length of the power supply cord or use of extension cord, and do not share 
     the single outlet with other electrical appliances. Otherwise, it will cause fire or electrical 
     shock.

CAUTION

1)  This equipment must be earthed and installed with earth leakage current breaker. It may cause
     electrical shock if grounding is not perfect.

2)  Do not install the unit at place where leakage of flammable gas may occur. In case gas leaks 
     and accumulates at surrounding of the unit, it may cause fire.

3)  Carry out drainage piping as mentioned in installation instructions. If drainage is not perfect, 
     water may enter the room and damage the furniture.

4)  For the unit adopts auxiliary electric heater, keep at least 1 meter away  from the nearest 
     combustible materials. 

SAFETY PRECAUTIONS

SAFETY PRECAUTIONS

Warning .....................................................................................................................................2
Caution ......................................................................................................................................2

INSTALLATION INSTRUCTIONS

Selecting installation place.........................................................................................................3
Accessories ........ .....................................................................................................................3
Indoor & outdoor unit installation drawings ...............................................................................4

TEST RUNNING

Test running ...................... .....................................................................................................14

INDOOR UNIT INSTALLATION 

Installation plate mounting..........................................................................................................5
Drill a hole in the wall ........ ......................................................................................................6
Connective pipe installation .......................................................................................................6
Drain piping.................................................................................................................................7
Connect the cable to the indoor unit............................................................................................7
Indoor unit installation..................................................................................................9

OUTDOOR UNIT INSTALLAITON

Outdoor installation precaution ..................................................................................................9
Settlement of outdoor unit ........................................................................................................10
Drain joint installation ...............................................................................................................10
Refrigerant pipe connection .....................................................................................................10
Connect the cable to the outdoor unit .....................................................................................12
Air purging.................................................................................................................................12

,

Summary of Contents for V4MVI-09WFR/V4MVO-09

Page 1: ...itioning system For correct use of this unit please read this manual carefully and keep it for future reference V4MVI 09WFR V4MVO 09 V4MVI 12WFR V4MVO 12 V4MVI 18WFR V4MVO 18 V4MVI 24WFR V4MVO 24 English Installation Manual Wall Mounted Unit ...

Page 2: ...An independent circuit and single outlet must be used If electrical circuit capacity is not enough or defect found in electrical work it will cause electrical shock or fire 6 Use the specified cable and connect tightly and clamp the cable so that no external force will be acted on the terminal If connection or fixing is not perfect it will cause heat up or fire at the connection 7 Wiring routing m...

Page 3: ...s Do not place any obstacles which may cause a short circuit of the discharged air Select a location which avoids causing a nuisance to neighbours from noise and air emissions from device Select a location which is sufficiently well ventilated Never cover the air inlets and outlets The location must be sufficientlyfirm for installation and the prevention of vibrations There must be no risk present...

Page 4: ...rom rear of the indoor unit is gathered in ponding box and is piped out of room Do not put anything else in the box Fig 4 1 For the left hand and right hand piping remove the pipe cover from the side panel 2 For the right back and left back piping install the piping as shown NOTE 3 Attach the drain hose to the underside of the refrigerant pipes with adhesive viny tape 4 Wrap the refrigerant pipes ...

Page 5: ...Max Current ofthe unit should be installed in power circuit Ensurethe air conditioner is groundedwell 4 The appliance shall beinstalled in accordance with nationalwiring regulations Do not operate your air conditioner in a wet roomsuch as a bathroom orlaundry room 5 An all poledisconnection device which has atleast 3mm clearances in allpoles and have a leakage current that may exceed10mA the resid...

Page 6: ...ion Determine the air outlet direction where the discharged air is not blocked In the case that the installation place is exposed to strong wind such as a seaside make sure the fan operating properly by putting the unit lengthwise along the wall or using a dust or shield plates Specially in windy area install the unit to prevent the admission of wind If need suspending installation the installatio...

Page 7: ...wn in Fig 16 17 2 Tightening Connection Excessive torque can break nut depending on installation conditions Indoor unit tubing Flare nut Pipings Fig 16 Outer diam mm A mm Max Min 6 35 1 3 0 7 9 52 1 6 1 0 12 7 1 8 1 0 12 7 16 1 8 2 2 1 0 2 0 Outer diam Tightening torque N cm Additional tightening torque N cm 6 35 12 7 16 9 52 1500 153kgf cm 1600 163kgf cm 3500 357kgf cm 3600 367kgf cm 2500 255kgf ...

Page 8: ...lect the AUTO or COOL the unit will operate under Forced AUTOor COOL mode see User Manual for details 4 The testoperation should last about 30 minutes When relocate the unit to another place perform evacuation using vacuum pump Make sure the refrigerant added into the air conditioner is liquid form in any case Not applicable to the units adopt freon R22 Open the valve stem until it hits against th...

Reviews: