TAKE NOTE OF FUSE SPECIFICATIONS
The air conditioner’s circuit board (PCB) is
designed with a fuse to provide overcurrent
protection. The specifications of the fuse
are printed on the circuit board, such as:
Indoor unit:
T5A/250VAC
Outdoor unit
(applicalbe to units adpot
R32 or R290 refrigerant only)
:
T20A/250VAC(<=18000Btu/h units)
T30A/250VAC(>18000Btu/h units)
NOTE: The fuse is made of ceramic.
1.
Prepare the cable for connection:
a.
Using wire strippers, strip the rubber jacket
from both ends of signal cable to reveal
about 40mm (1.57in) of the wires inside.
b.
Strip the insulation from the ends of the
wires.
c.
Using wire crimper, crimp u-type lugs on
the ends of the wires.
PAY ATTENTION TO LIVE WIRE
While crimping wires, make sure you clearly
distinguish the Live (“L”) Wire from other wires.
2. Open front panel of the indoor unit by loosen
the screws according to picture Fig.4.7, which
provide big space for wiring connection.
3.
Open the wire box cover to connect the cable.
WARNING
4. Unscrew the cable clamp below the terminal
block and place it to the side.
5. Facing the back of the unit, remove the plastic
panel on the bottom left-hand side.
ALL WIRING MUST PERFORMED STRICTLY
IN ACCORDANCE WITH THE WIRING
DIAGRAM LOCATED ON THE INSIDE OF
THEINDOOR UNIT’S WIRE COVER.
Terminal
block
Wire
cover
Cable
clamp
Fig. 3.13
The Wiring Diagram is located
on the inside of the indoor unit’s
wire cover.
6. Feed the signal wire through this slot, from
the back of the unit to the front.
7. Facing the front of the unit, match the wire
colors with the labels on the terminal block,
connect the u-lug and and firmly screw each
wire to its corresponding terminal.
CAUTION
DO NOT MIX UP LIVE AND NULL WIRES
This is dangerous, and can cause the air
conditioning unit to malfunction.
8. After checking to make sure every connection
is secure, use the cable clamp to fasten the
signal cable to the unit. Screw the cable clamp
down tightly.
9. Replace the wire cover on the front of the
unit, and the plastic panel on the back.
NOTE ABOUT WIRING
THE WIRING CONNECTION PROCESS
MAY DIFFER SLIGHTLY
BETWEEN UNITS.
Page 19
Step 7: Wrap piping and cables
Before passing the piping, drain hose, and the
signal cable through the wall hole, you must
bundle them together to save space, protect
them, and insulate them.
1. Bundle the drain hose, refrigerant pipes, and
signal cable according to
Fig. 3.14.
Indoor Unit
Space behind unit
Refrigerant piping
Drain hose
Signal wire
Insulation tape
DRAIN HOSE MUST BE ON BOTTOM
Make sure that the drain hose is at the bottom
of the bundle. Putting the drain hose at the
top of the bundle can cause the drain pan
to overflow, which can lead to fire or water
damage.
DO NOT INTERTWINE SIGNAL CABLE WITH
OTHER WIRES
While bundling these items together, do not
intertwine or cross the signal cable with any
other wiring.
2. Using adhesive vinyl tape, attach the drain
hose to the underside of the refrigerant pipes.
3. Using insulation tape, wrap the signal wire,
refrigerant pipes, and drain hose tightly
together. Double-check that all items are
bundled in accordance with
Fig. 3.14.
DO NOT WRAP ENDS OF PIPING
When wrapping the bundle, keep the ends
of the piping unwrapped. You need to access
them to test for leaks at the end of the
installation process (refer to
Electrical Checks
and Leak Checks
section of this manual).
Step 8: Mount indoor unit
If you installed new connective piping to the
outdoor unit,
do the following:
1. If you have already passed the refrigerant
piping through the hole in the wall, proceed
to Step 4.
2. Otherwise, double-check that the ends of the
refrigerant pipes are sealed to prevent dirt or
foreign materials from entering the pipes.
3. Slowly pass the wrapped bundle of refrigerant
pipes, drain hose, and signal wire through the
hole in the wall.
4. Hook the top of the indoor unit on the upper
hook of the mounting plate.
5. Check that unit is hooked firmly on mounting
by applying slight pressure to the left and
right-hand sides of the unit. The unit should
not jiggle or shift.
6. Using even pressure, push down on the
bottom half of the unit. Keep pushing down
until the unit snaps onto the hooks along the
bottom of the mounting plate.
7. Again, check that the unit is firmly mounted
by applying slight pressure to the left and the
right-hand sides of the unit.
Fig. 3.14
Summary of Contents for P9MVI32-09WiFi
Page 41: ......
Page 43: ...25 29 6 7 8 9 10 34 11 MC MC R32 R290 31 32 34 1 29 2 30 25 B 25 1 25 2 26 3 26 4 27...
Page 44: ...4 Page 4 1 2 C C C 3 4 5 6 7 8 9 10 7 10 R32 R290...
Page 45: ...5 Page 5 11 12 13 14 15 16 8 1 3 1 2 3 4 1 2 3 4 12 5...
Page 46: ...6 1 1 1 1 5 5 2 1 2 Page 6 ST3 9 X 25 M LR03 ST2 9 x 10...
Page 48: ...8 8 11 12 12 12 1 2 3 4 12cm 4 75in 2 3m 90 55in 12cm 4 75in 15cm 5 9in 2...
Page 49: ...9 9 STEP 8 1 2 3 5 6 7 8 9 25 17 19 16 19...
Page 51: ...11 Page 11 4 Fig 3 1 a 1 o o o o o o 1 c c c...
Page 55: ...15 Page 15 Fig 3 6 Fig 3 7 Fig 3 8 3 3 15cm 6in 2 3 4 5 6 7 1 2 3 8 3 6 3 7 3 8...
Page 59: ...19 Page 19 Fig 3 14 7 1 3 14 2 3 3 14 8 1 4 2 3 4 5 6 7 3 14...
Page 61: ...21 Page 21 A B Fig 4 2 Fig 4 3 Fig 4 4 90 4 2 4 3 4 4 1 2 3 90 4 4 4 1 2 4 3 4 2 4 4 2...
Page 63: ...23 Page 23 1 2 3 4 5 6 7 8 4 1 2 3 4 90 100 5 1 5 6 1 8in 3mm 7 8 9 10 11 1 40in...
Page 68: ...28 Page 28 Fig 5 9 Fig 5 10 5 6 7 3 6 5 9 5 10 1 5 9 2 3 4...
Page 69: ...29 Page 29 7 76cmHg MC MC Fig 6 1 o o 1 2 3 4 5 15 76cmHG 105Pa 6 1...
Page 71: ...31 Page 31 8 4...
Page 72: ...32 Page 32 9 30 1 2 ON OFF 3 MODE 4 5 2 2...
Page 74: ...34 Page 34 10...
Page 75: ...35 Page 35 11 R32 R290 1 2 3 4 5 6 7 8 l...
Page 76: ...36 l l l l O 9 l l 10 10 1 10 2 l l...
Page 77: ...37 11 12 13 14 LFL 25 OFN 15 l l l l l OFN OFN...
Page 78: ...38 OFN 16 l l l l l l OFN 17 l l l l 80...
Page 79: ...39 18 19 l l l l l l l 20 1 2 3 4 5...
Page 118: ...NOTES...
Page 119: ......