MODEL A
MODEL B
Foam seal B
(Adhesive type-shorter)
Foam seal A
(Adhesive type)
Window slider A Window slider B
(if required)
VENT CONTROL feature
CLOSE
OPEN
max 120cm or 47 inch
min 30cm or 12 inch
Expansion anchor
position
Adaptor cap
Wall Exhaust
Adaptor B
|Installation
|Installation
Note:
Once the Exhaust Hose assembly and
Adjustable Window Slider are prepared, choose
from one of the following installation methods.
Type 1:
Hung Window or Sliding Window
Installation (optional)
Type 2:
Wall Installation (optional)
1.Cut a 125mm (4.9inch) hole into the wall
for the Wall Exhaust Adaptor B. 2.Secure the
Wall Exhaust Adaptor B to the wall using the
four Anchors and Screws provided in the kit.
3.Connect the Exhaust Hose Assembly (with
Wall Exhaust Adaptor A) to the Wall Exhaust
Adaptor B.
1. Cut the foam seal (adhesive type) to the
proper length and attach it to the window
frame.
2. Attach the window slider kit to the window
opening.
4.If desired, install the security bracket with 2
screws as shown.
5.Insert the window slider adaptor into the hole
of the window slider.
3.Cut the non- adhesive foam seal C strip to match
the width of the window. Insert the seal between
the glass and the window frame to prevent air and
insects from getting into the room.
Note: Cover the hole
using the adaptor cap
when not in use.
Note:
To ensure proper function, DO NOT
overextend or bend the hose. Make sure that
there is no obstacle around the air outlet of the
exhaust hose (in the range of 500mm) in order
to the exhaust system works properly. All the
illustrations in this manual are for explanation
purpose only.
Your air conditioner may be slightly different.
The actual shape shall prevail.
The Vent Control is located at the back of the
air conditioner. The OPEN position removes
stale air from the room and exhausts it to the
outside. Fresh air is drawn in through normal
passages in the home.
When not need to circulate the room air, set
Vent Control to CLOSE position. This function is
only applicable for MODEL B.
Summary of Contents for M2GHP290-12
Page 22: ...22 GR 23 R290 R32 25 31 34 38 39 40 41...
Page 23: ...GR 23 1 PCB 3 15A 250V...
Page 24: ...24 GR 8...
Page 26: ...26 GR 1 2 3 4 5 6 CO2 7 8 R290 R32...
Page 27: ...GR 27 9 10 11 12 13 14 O R290 R32...
Page 28: ...28 GR LFL O LFL 25 15 16 17 R290 R32...
Page 29: ...GR 29 80 18 19 CO2 R290 R32...
Page 30: ...30 GR MODE L A M OD EL B SCALE 0 500...
Page 31: ...GR 31 50cm 19 7inch 30cm 12 Philips...
Page 39: ...GR 39 ON OFF P1 COOL...
Page 63: ...EN 63...
Page 64: ...64 EN PORTABLE AIR CONDITIONING SYSTEMS v 1 0...