26
EN
In the event of any of the above-mentioned errors, all buttons are
unavailable, except for the “POWER” button so that the device can
be turned off. After powering off, unplug the device for 10minutes
to reset. When device is turned back on check if the error persists.
In case the error persists, the unit should remain turned off and
unplugged. Contact the manufacturer or a qualified technician for
service.
14. INSTRUCTION FOR REPAIRING APPLIANCES
CONTAINING REFRIGERANT R290
1. Checks to the area
Prior to beginning work on systems containing flammable refrigerants, safety checks are
necessary to ensure that the risk of ignition is minimized. For repair to the refrigerating
system, the following precautions shall be complied with prior to conducting work in the
system.
Work procedure
Work shall be undertaken under a controlled procedure so as to minimize the risk of a
flammable gas or vapor being present while the work is being performed.
2. General work area
All maintenance staff and others working in the local area shall be instructed on the nature
of work being carried out. Work in confined spaces shall be avoided. The area around the
workspace shall be sectioned off. Ensure that the conditions within the area have been
made safe by control of flammable material.
3. Checking for presence of refrigerant
The area shall be checked with an appropriate refrigerant detector prior to and during
work, to ensure the technician is aware of potentially flammable atmospheres. Ensure that
the leak detection equipment being used is suitable for use with flammable refrigerants,
i.e. nonspeaking, adequately sealed or intrinsically safe.
4. Presence of fire extinguisher
If any work is to be conducted on the refrigeration equipment or amy associated parts,
appropriate fire extinguishing equipment shall be available to hand. Have a dry powder or
CO
2
fire extinguisher adjacent to the charging area.
5. No ignition sources
No person carrying out work in relation to a refrigeration system which involves exposing
any pipe work that contains or has contained flammable refrigerant shall use any sources
of ignition in such a manner that it may lead to the risk of fire or explosion. All possible
ignition sources, including cigarette smoking, should be kept sufficiently far away from the
site of installation, repairing, removing and disposal, during which flammable refrigerant
can possibly be released to the surrounding space. Prior to work taking place, the area
around the equipment is to be surveyed to make sure that there are no flammable hazards
or ignition risks.”No Smoking” signs shall be displayed.
Summary of Contents for CF-WUHI-16L
Page 2: ...LANGUAGES ENGLISH 3 33 ROMANA 65...
Page 34: ...34 GR 1 l 220 240V 50Hz l l l 30 l l l l l l l 8 l l l l l l l l l...
Page 35: ...35 GR l l l l l l l l l l l l l l l 24...
Page 36: ...36 GR 2 l l l l l l l l PCB T 3 15A 250V 350V 3 l 2002 96 EC 27 2003 l CO2 l A B...
Page 37: ...37 GR 4 R290 l l To R290 l l R290 R290...
Page 38: ...38 GR 5 SN D2002255780115715200209 SN D2002255780115715200209 A SN...
Page 39: ...39 GR A 1 30cm 40cm 2 5 C 5 C 5 C 35 C 30 90 3 4 2 5...
Page 40: ...40 GR 6 HEPA...
Page 48: ...48 GR 8 O O O TIMER Hi 91 Hi 90...
Page 51: ...51 GR 10 1 2...
Page 52: ...52 GR x x...
Page 53: ...53 GR 15 11 l o l 2 l HEPA 30...
Page 54: ...54 GR 12 24 13 HEPA 45 55...
Page 55: ...55 GR display 5 C 41 F...
Page 56: ...56 GR l l l l l l l l l l l l l l l l l l l l l l l C1 C2 C8 3 C...
Page 57: ...57 GR POWER 10 14 R290 1 2 3 4 CO2 5...
Page 58: ...58 GR 6 7 8 9...
Page 59: ...59 GR 10 11 12 13 O LFL 25 14...
Page 60: ...60 GR 15 16...
Page 61: ...61 GR 80 17 18...
Page 62: ...62 GR 19 20 21 22...
Page 63: ...63 GR 211 300 3300 www inventoraircondition gr media library...
Page 95: ......