53
10. Removal Procedure
10.1 Removal Procedure of Indoor Unit
Warning Be sure to wait 10 minutes or more after turning
off all power supplies before disassembling work.
1. External features
2. Removing air filters
If ON/OFF button is kept pushing
for 5 seconds, aforced cooling op-
eration willbe carried out for
approx. 15minutes.
Pull protrusions on left
and right sides of panel
with fingers and open
front grille all the way.
1
Lift center section of air
filter and disengage
hooks.
2
Left and right filters are
interchangeable.
To re-install, insert air filter
along the guide.
Remove air filter by
pulling forward.
3
Hooks
Air filter
Removal Procedure